Buttons shall be arranged with numbers in ascending order. When two or more columns of buttons are provided they shall read from left to right.
Search Results "Elevator Car Designation"
-
11B-407.4.6.2.2 Arrangement
-
11B-411.4.6.1 Location
Controls shall be located within one of the reach ranges specified in Section 11B-308.
-
407.4.8.1.4 Destination Indicator
In destination-oriented elevators, a display shall be provided in the car with visible indicators to show car destinations....
-
11B-411.4.8.1 Visible indicators
Visible indicators shall comply with Section 11B-411.4.8.1.
-
11B-411.4.8.1 Visible indicators
Visible indicators shall comply with Section 11B-411.4.8.1.
-
11B-411.4.8.1 Visible indicators
Visible indicators shall comply with Section 11B-411.4.8.1.
-
11B-407.4.8.1.4 Reserved.
In destination-oriented elevators, a display shall be provided in the car with visible indicators to show car destinations....
-
DESIGNATED PUBLIC TRANSPORTATION
[DSA-AC] Transportation provided by a public entity (other than public school transportation) by bus, rail, or other conveyance (other than transportation by aircraft or intercity or...
-
DESIGNATED PUBLIC TRANSPORTATION
[DSA-AC] Transportation provided by a public entity (other than public school transportation) by bus, rail, or other conveyance (other than transportation by aircraft or intercity or...
-
11B-407.4.8.1.4 Reserved
In destination-oriented elevators, a display shall be provided in the car with visible indicators to show car destinations....
- Schumacher 1400 Series Limited Use Limited Application (LULA) Elevator
-
11B-408.3.2 Swinging doors
Swinging hoistway doors shall open and close automatically and shall comply with Sections 11B-404, 11B-407.3.2 and 11B-408.3.2.
-
11B-408.3.2 Swinging doors
Swinging hoistway doors shall open and close automatically and shall comply with Sections 11B-404, 11B-407.3.2 and 11B-408.3.2.
-
11B-206.6.1 Existing elevators
Where elements of existing elevators are altered, the same element shall also be altered in all elevators that are programmed to respond to the same hall call control as the altered elevator...
-
11B-206.6.1 Existing elevators
Where elements of existing elevators are altered, the same element shall also be altered in all elevators that are programmed to respond to the same hall call control as the altered elevator...
-
11B-411.4.7.3 Symbols
The control button for the emergency stop, alarm, door open, door close, and phone, shall be identified with raised symbols and Braille as shown in Table 11B-407.4.7.1.3.
-
11B-407.4.8.2.2 Signal level
The verbal annunciator shall be 10 dB minimum above ambient, but shall not exceed 80 dB, measured at the annunciator.
-
11B-407.4.8.2.2 Signal level
The verbal annunciator shall be 10 dB minimum above ambient, but shall not exceed 80 dB, measured at the annunciator.
-
11B-411.4.7.3 Symbols
The control button for the emergency stop, alarm, door open, door close, and phone, shall be identified with raised symbols and Braille as shown in Table 11B-407.4.7.1.3.
-
408.3 Elevator Doors
408.3 Elevator Doors. Elevator hoistway doors shall comply with 408.3....
-
407.4 Elevator Car Requirements
Elevator cars shall comply with 407.4....
-
407.4 Elevator Car Requirements
Elevator cars shall comply with 407.4....
-
PASSENGER ELEVATOR
[DSA-AC] See “Elevator, Passenger”....
-
PASSENGER ELEVATOR
[DSA-AC] See “Elevator, Passenger”....