This section requires the clear tread width of trails to be 36 inches minimum....
Search Results "Door Clear Width"
-
1017.3 Clear Tread Width
-
11B-809.8.1 Door Thresholds
Primary entry doors, required exit doors, and interior doors intended for user passage shall have thresholds complying with Section 11B-404.2.5....
-
Guest Rooms
Because of the social interaction that often occurs in lodging facilities, an accessible clear opening width is required for doors and doorways to and within all guest rooms, including those...
-
Double-Leaf Doors and Gates: ADA Standard Section 404.2.2
Section 404.2.2 covers the current ADA Standards for double-leaf doors and gates that are part of an accessible route.
-
803.3 Door Swing
Doors shall not swing into the room unless a clear floor or ground space complying with 305.3 is provided beyond the arc of the door swing....
-
803.3 Door Swing
Doors shall not swing into the room unless a clear floor or ground space complying with 305.3 is provided beyond the arc of the door swing....
-
10.3.1(16)
(16) Where provided in below grade stations, escalators shall have a minimum clear width of 32 inches....
-
7.3(2)
(2) Clear aisle width for accessible check-out aisles shall comply with 4.2.1 and maximum adjoining counter height shall not exceed 38 in (965 mm) above the finish floor....
-
Accessible Route
accessible route but where they are required to comply with 4.9, it is recommended that routes to them meet the requirements for accessible routes since certain specifications, such as clear...
-
405.5 Clear Width
The clear width of a ramp run and, where handrails are provided, the clear width between handrails shall be 36 inches (915 mm) minimum....
-
405.5 Clear Width
The clear width of a ramp run and, where handrails are provided, the clear width between handrails shall be 36 inches (915 mm) minimum....
-
Clear Deck Space: ADA Standard Section 1009.4.1
A clear deck space of 60 inches (1525 mm) minimum by 60 inches (1525 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer wall....
-
Manual Doors, Doorways, and Manual Gates: ADA Standard Section 404.2
Section 404.2 covers the current ADA Standards for manual doors, doorways and manual gates that are part of an accessible route.
-
11B-404.2.4.3 Recessed doors and gates
, measured perpendicular to the face of the door or gate...
-
11B-404.2.4.3 Recessed doors and gates
, measured perpendicular to the face of the door or gate...
-
Handrails
The clear width between handrails must be between 33 and 38 inches. The handrail height must be between 34 and 38 inches to the top of the gripping surface....
-
11B-411.3.4 Door delay
Door delay shall comply with Section 11B-407.3.5....
-
11B-411.3.4 Door delay
Door delay shall comply with Section 11B-407.3.5....
-
603.2.3 Door Swing
Doors shall not swing into the clear floor space or clearance required for any fixture. Doors shall be permitted to swing into the required turning space. EXCEPTIONS: 1....
-
11B-404.2.2 Double-leaf doors and gates
At least one of the active leaves of doorways with two leaves shall comply with Sections 11B-404.2.3 and 11B-404.2.4.
-
11B-404.2.2 Double-leaf doors and gates
At least one of the active leaves of doorways with two leaves shall comply with Sections 11B-404.2.3 and 11B-404.2.4.
-
11B-1009.2.5 Seat width
The seat shall be 16 inches (406 mm) wide minimum.
-
11B-1009.2.5 Seat width
The seat shall be 16 inches (406 mm) wide minimum.
-
8.5 Stacks
Minimum clear aisle width between stacks shall comply with 4.3, with a minimum clear aisle width of 42 in (1065 mm) preferred where possible....