Clearance around a water closet shall be 60 inches (1525 mm) minimum measured perpendicular from the side wall and 56 inches (1420 mm) minimum measured perpendicular from the rear wall....
Search Results "Closet Door"
Commonly Searched Documents
-
604.3.1 Size
-
404.2.1 Revolving Doors, Gates, and Turnstiles
Revolving doors, revolving gates, and turnstiles shall not be part of an accessible route....
-
404.2.1 Revolving Doors, Gates, and Turnstiles
Revolving doors, revolving gates, and turnstiles shall not be part of an accessible route....
-
Maneuvering Clearance or Standby Power for Automatic Doors
Maneuvering Clearance or Standby Power for Automatic Doors. Section 4.13.6 of the 1991 Standards does not require maneuvering clearance at automatic doors....
-
Attachment E
The entrance door to the school leading to the shelter area has two single doors in series with insufficient maneuvering space within the vestibule. ...
-
Power Operation: ADA Standard Section 409.3.1
Section 409.3.1 covers the current ADA Standards for the power operation of private residence elevator doors.
-
Doors and hardware
• Minimum-weight doors with accessible hardware are easily opened by people who have arthritis or use a cane for extra balance....
-
4.10.8 Door Delay for Car Calls
The minimum time for elevator doors to remain fully open in response to a car call shall be 3 seconds....
-
4.10.8 DOOR DELAY FOR CAR CALLS
The minimum time for elevator doors to remain fully open in response to a car call shall be 3 seconds....
-
604.3.1 Size
Clearance around a water closet shall be 60 inches (1525 mm) minimum measured perpendicular from the side wall and 56 inches (1420 mm) minimum measured perpendicular from the rear wall....
-
Doors and Gates Operated Only By Security Personnel [§404.1, Ex]
Doors and Gates Operated Only By Security Personnel [§404.1, Ex] Manual doors, doorways, and gates that are designed to be operated only by security personnel, such as guards in...
-
Door Hardware
A few commenters requested that lever hardware be required on doors throughout dwelling units, not only at the entry door to the dwelling unit. Response....
-
3. Doors
Doors with 32 inches of clear opening width (when a sliding door is fully opened or a hinged door is open 90 degrees). Clear floor space is required in front of the door....
-
Double Action Door Pressure Gauge
Double Action Door Pressure Gauge This Door Pressure Gauge, available from Evan Terry Associates, has Push-Pull capability and measures forces from 0-35 pounds on one side and 0-16...
-
4.13.11(2)(c)
(c) sliding or folding doors: 5 lbf (22.2N) These forces do not apply to the force required to retract latch bolts or disengage other devices that may hold the door in a closed position...
-
5.3.3.2 Location Where Walls Provided
Where walls or partitions are provided, the seat shall be positioned with a wall or partition to the rear and to one side of the seat for a left-hand or right-hand approach. The back...
-
Low Energy Doors and Gates [§404.3]
Low Energy Doors and Gates [§404.3] Low energy doors and gates usually require activation by the user through a push plate or control and are often used in moderate traffic locations...
-
SECTION 1132A DOORS
SECTION 1132A DOORS...
-
A. Slope at Door
If a fully automatic door is not provided, is the walkway in front of the lobby door level, without any portion steeper than 1:50 (critical dimension of ´" or less), so persons who use wheelchairs...
-
304.4 Door Swing
Doors shall be permitted to swing into turning spaces....
-
304.4 Door Swing
Doors shall be permitted to swing into turning spaces....
-
604.3 Clearance
Clearances around water closets and in toilet compartments shall comply with 604.3....