- Hussey Seating Company Armless Chair
-
11B-201.1 Scope, 11B-201.2 Application based on building or facility use, 11B-202.2 Additions, 11B-202.3 Alterations
Alteration of single elements shall comply with the applicable requirements of Division 2 for that element....
-
203.1 General
Sites, buildings, facilities, and elements are exempt from these requirements to the extent specified by 203....
-
11B-604.3.2 Overlap
The required clearance around the water closet shall be permitted to overlap the water closet, associated grab bars, dispensers, sanitary napkin disposal units, coat hooks, shelves,...
-
11B-608.5.3 Alternate roll-in type shower compartments
In alternate roll-in type shower compartments, the controls, faucets, and shower spray unit shall be located on the side wall of the compartment adjacent to the 16 inches (406 mm)...
-
Parallel Approach to Kitchen Sinks
Comment. Commenters recommended that a parallel approach should be allowed at kitchen sinks in spaces without a cook top or conventional range, consistent with the ANSI A117.1...
-
608.3.1 Transfer Type Shower Compartments
In transfer type compartments, grab bars shall be provided across the control wall and back wall to a point 18 inches (455 mm) from the control wall. Figure 608.3.1 Grab Bars...
-
608.3.1 Transfer Type Shower Compartments
In transfer type compartments, grab bars shall be provided across the control wall and back wall to a point 18 inches (455 mm) from the control wall.
-
Equipment and furniture.
Question seven of the ANPRM asked for comment on whether regulatory guidance is needed with respect to the acquisition and use of mobile, portable, and other free-standing equipment...
-
2. Roll-in Shower Size
2. If there are more than 50 guestrooms/suites, are all required roll-in showers at least 30" wide by 60" long or 36" wide by 60", as configured in Figure 57 below, so persons who...
-
608.3.1 Transfer Type Shower Compartments
608.3.1 Transfer Type Shower Compartments. In transfer type compartments, grab bars shall be provided across the control wall and back wall to a point 18 inches (455 mm) from the...
-
Q. Other Showers in Accessible Guestrooms/Suites
Q. Other Showers in Accessible Guestrooms/Suites - Accessible guestrooms/suites that are not required to have roll-in showers may have an accessible bathtub, a small shower as shown...
-
12162(e)(2)(B)(ii) Alterations to a primary function area
(ii) Alterations to a primary function area It shall be considered discrimination, for purposes of section 12132 of this title and section 794 of title 29, with respect to...
-
Sinks [4.24]
Sinks [4.24] ADAAG provides technical specifications for both "lavatories" and "sinks." Requirements for lavatories in ADAAG 4.19 apply to fixtures for hand washing in toilet or...
-
4.24.3 Knee Clearance
Knee clearance that is at least 27 in (685 mm) high, 30 in (760 mm) wide, and 19 in (485 mm) deep shall be provided underneath sinks.
-
4.24.3 KNEE CLEARANCE
Knee clearance that is at least 27 in (685 mm) high, 30 in (760 mm) wide, and 19 in (485 mm) deep shall be provided underneath sinks.
-
3.2.6 Identification of Accessible Camping Units
Accessible camping units shall be identified at an entrance kiosk, on a bulletin board, or on a sign at the registration area of a campground. They shall not be identified using...
-
Bathtub
Bathtub Grab Bars. As getting in and out of a tub is generally considered to be a falls risk for individuals, designers were not encouraged to promote independent bathing in...
-
11B-608.3.1 Reserved
11B-608.3.1 Reserved.
-
11B-211 Drinking fountains and bottle filling stations
11B-211 Drinking fountains and bottle filling stations
-
11B-608.3.1 Transfer type shower compartments
In transfer type compartments, grab bars shall be provided across the control wall and back wall to a point 18 inches (457 mm) from the control wall.
-
11B-602 Drinking fountains and bottle filling stations
11B-602 Drinking fountains and bottle filling stations
-
4.34.2(3)
(3) At least one accessible route complying with 4.3 shall connect the accessible entrances with all accessible spaces and elements within the dwelling units....
-
Re: SCOTT JOHNSON v. STARBUCKS CORPORATION - AMICUS BRIEF
Note that this requirement specifically applies to movable elements and is a broad obligation that would clearly apply to display items on a sales counter at the point that any of them become...