3M’s high-tech POF protects sign faces against fading caused by the sun and harsh weather—and makes graffiti and sticker defacement damage easy to clear away without harsh abrasives....
Search Results "Clear Pier Space"
Commonly Searched Documents
- Stop Signs and More Disabled Passenger Loading Zone Only Sign
- Rockwood Manufacturing Company 603 Door Guard - Cast Aluminum
- Magnuson Group VALUTA Waste Receptacles
-
4.13.7 Two Doors in Series
The minimum space between two hinged or pivoted doors in series shall be 48 in (1220 mm) plus the width of any door swinging into the space....
-
4.13.7 TWO DOORS IN SERIES
The minimum space between two hinged or pivoted doors in series shall be 48 in (1220 mm) plus the width of any door swinging into the space....
-
11B-407.4.7.1.2 Location
[2010 ADA Standards] EXCEPTION: Where space on an existing car operating panel precludes tactile markings to the left of the controls, markings shall be placed as near to the control...
-
1129B.3, Item 2
SECTION 1129B - ACCESSIBLE PARKING REQUIRED 1129B.3 Parking space size. ...
-
11B-404.3.6 Break out opening
Where doors and gates without standby power are a part of a means of egress, the clear break out opening at swinging or sliding doors and gates shall be 32 inches (813 mm) minimum when operated...
-
10. Can a transfer platform be an irregular shape as long as it incorporates the minimum rectangle of 14 by 24 inches?
It is recommended that the clear edge provided for transfer be a straight edge. The 24 inch side of the transfer platform must be free from obstructions to allow a person to transfer....
-
404.3.6 Break Out Opening
Where doors and gates without standby power are a part of a means of egress, the clear break out opening at swinging or sliding doors and gates shall be 32 inches (815 mm) minimum when operated...
-
The American Dream
The American Dream The time has come for the Senate to send a loud, clear message across this country: Individuals with disabilities, no less than all other Americans, are entitled to...
-
11B-608.2.3 Alternate roll-in type shower compartments
Alternate roll-in type shower compartments shall be 36 inches (914 mm) wide and 60 inches (1524 mm) deep minimum clear inside dimensions measured at center points of opposing sides....
-
11B-404.3.6 Break out opening
Where doors and gates without standby power are a part of a means of egress, the clear break out opening at swinging or sliding doors and gates shall be 32 inches (813 mm) minimum when operated...
-
11B-404.3.6 Break out opening
Where doors and gates without standby power are a part of a means of egress, the clear break out opening at swinging or sliding doors and gates shall be 32 inches (813 mm) minimum when operated...
-
11B-405.8 Handrails
Ramps not subject to the exception to 405.5 shall be designed to maintain a 36 inch (915 mm) minimum clear width when handrails are installed....
- Seton Parking Sign with ISA
- Kompan, Inc. Explorer ELE400008
-
11B-502.5 Vertical clearance
Parking spaces for vans and access aisles and vehicular routes serving them shall provide a vertical clearance of 98 inches (2490 mm) minimum. ...
- Rebuilding Together Twin Cities - Minneapolis, MN
-
4.6.4* Signage
Accessible parking spaces shall be designated as reserved by a sign showing the symbol of accessibility (see 4.30.7)....
-
T704 Announcement Systems
For stop announcement systems, signs must be provided onboard and be viewable from all wheelchair spaces and priority seats....
-
Re: 405 Ramps
Gentlemen/Ladies: While the code requires a 60"x 60" clear landing, does it have to be square? Please see attached and advise, thank you....
-
11B-502.5 Vertical clearance
Parking spaces, access aisles and vehicular routes serving them shall provide a vertical clearance of 98 inches (2489 mm) minimum. [2010 ADAS] 502.5 Vertical Clearance. ...
-
11B-502.5 Vertical clearance
Parking spaces, access aisles and vehicular routes serving them shall provide a vertical clearance of 98 inches (2489 mm) minimum. [2010 ADAS] 502.5 Vertical Clearance. ...