Exception: Where a single clear floor space complying with Section 11B-305 positioned for parallel approach is provided between two beds, a clear floor or ground space shall not be required...
Search Results "Ground Surface"
-
11B-806.2.3 Sleeping areas
-
11B-806.2.3 Sleeping areas
Exception: Where a single clear floor space complying with Section 11B-305 positioned for parallel approach is provided between two beds, a clear floor or ground space shall not be required...
-
404.2.11 Vision Lights
EXCEPTION: Vision lights with the lowest part more than 66 inches (1675 mm) from the finish floor or ground shall not be required to comply with 404.2.11....
-
§ 36.406(e)(1)
sleeping rooms) or on floors containing accessible sleeping rooms with mobility features shall provide turning spaces that comply with section 809.2.2 of the 2010 Standards and kitchen work surfaces...
-
11B-407.4.10.1 Location
Clearance between support rails and adjacent surfaces shall be 1½ inches (38 mm) minimum....
-
Sec.36.304(e) Portable ramps
avoid any significant risk to the health or safety of individuals with disabilities or others in using portable ramps, due consideration shall be given to safety features such as nonslip surfaces...
-
11B-227.5 Queues and Waiting Lines
Queues and waiting lines servicing counters or check-out aisles required to comply with Sections 11B-904.3 or 11B-904.4 shall comply with Section 11B-403 _|Walking Surfaces|_. ...
-
Transfer Platform
Transfer Platform Each transfer system must have a platform on the deck surface so users can maneuver on and off the system from their mobility device or wheelchair....
-
Technical Requirements [1018 and 1018.1, Exception 3]
The technical requirements for beach access routes include specific provisions for connections, the surface, clear width, obstacles, openings, running slope, cross slope, resting intervals...
-
11B-505.10.2 Top extension at stairs
Extensions shall return to a wall, guard, or the landing surface, or shall be continuous to the handrail of an adjacent stair flight....
-
§ 36.304(e) Portable ramps
avoid any significant risk to the health or safety of individuals with disabilities or others in using portable ramps, due consideration shall be given to safety features such as nonslip surfaces...
-
Contrast
The domes and their matrix must also offer a strong visual contrast to adjacent pedestrian surfaces....
-
1132A.4, Item 4
Secondary exterior doors onto decks, patios or balcony surfaces constructed of impervious materials (e.g., concrete, brick, flagstone) may have a maximum change in height from the interior...
-
§ 38.101(b)
doorways of cars not operating at lighted station platforms shall have outside lights which, when the door is open, provide at least 1 footcandle of illumination on the station platform surface...
-
11B-707.6.3.2 Tactile symbols
Function key surfaces shall have tactile symbols as follows: Enter or Proceed key: raised circle; Clear or Correct key: raised left arrow; Cancel key: raised letter ex; Add Value key: raised...
-
11B-407.4.10.1 Location
Clearance between support rails and adjacent surfaces shall be 1½ inches (38 mm) minimum....
-
11B-407.4.10.1 Location
Clearance between support rails and adjacent surfaces shall be 1½ inches (38 mm) minimum....
-
11B-404.2.7 Door and gate hardware
Operable parts of such hardware shall be 34 inches (864 mm) minimum and 44 inches (1118 mm) maximum above the finish floor or ground....
-
References
Accessible Exterior Surfaces Technical Article. Washington, D.C.: U.S. Access Board. Axelson, P. W., Yamada, D. A., Kirschbaum, J. B., Longmuir, P....
-
Vanity Counter Space
Comparable vanity countertop space need not be one continuous surface and need not be exactly the same size as the countertops in comparable guest bathrooms....
-
11B-809.2.2 Turning space
For example, in kitchens, 804.3.1 requires at least one work surface with clear floor space complying with 306 to be centered beneath....
-
1003.2.12.2 Opening limitations
From a height of 34 inches (864 mm) to 42 inches (1067 mm) above the adjacent walking surfaces, a sphere 8 inches (203 mm) in diameter shall not pass....
-
Elevated Dune Crossings
Locate handrails continuously along both sides of the dune crossing at a height of 34 inches (865 millimeters) to 38 inches (965 millimeters) above the walking surface....
-
Suggestion by Eldon Tipping
in Concrete Construction magazine, September 1998, Eldon Tipping made suggestions for a specification for sloped random - traffic floors such as parking decks, ramps, and other sloped surfaces...