Self-service storage facilities shall provide individual self-service storage spaces complying with these requirements in accordance with Table 11B-225.3....
Search Results "Seating Space"
-
11B-225.3 Self-service storage facilities
-
11B-225.3 Self-service storage facilities
Self-service storage facilities shall provide individual self-service storage spaces complying with these requirements in accordance with Table 11B-225.3....
-
11B-208.2 Minimum number
Where more than one parking facility is provided on a site, the number of accessible spaces provided on the site shall be calculated according to the number of spaces required for each parking...
-
11B-208.2 Minimum number
Where more than one parking facility is provided on a site, the number of accessible spaces provided on the site shall be calculated according to the number of spaces required for each parking...
-
General: ADA Standard Section 216.1
Section 216.1 of the ADA Standards covers information in the current ADA Standards on scoping requirements for signs.
-
12. Staff
.: installing bathtub seats, lowering adjustable shower wands, placing folding seats in transfer showers in the down position, installing auxiliary fire alarm strobes into the building alarm...
-
11B-608.5.1 Reserved
In transfer type shower compartments, the controls, faucets, and shower spray unit shall be installed on the side wall opposite the seat 38 inches (965 mm) minimum and 48 inches (1220 mm...
-
§ 37.167(j)(4)
(4) In all signage designating priority seating areas for elderly persons and persons with disabilities, or designating wheelchair securement areas, the entity shall include language informing...
-
§ 38.95(a)(1) General
., lift, ramp or bridge plate) complying with either paragraph (b) or (c) of this section; sufficient clearances to permit a wheelchair or mobility aid user to reach a seating location;...
-
233.4.2
233.4.2 Facilities with more than 50 beds covered that provide common use bathing facilities shall provide at least one roll-in shower with a seat that complies with section 608....
-
Standards for Individual Captioning Devices (Section-by-Section Analysis)
The Department received a number of comments expressing concern that seat location can have an impact on the ability to read closed captions. ...
-
Location of accessible routes to stages. (Section-by-Section Analysis)
The 1991 Standards, at section 4.33.5, require an accessible route to connect the accessible seating and the stage, as well as other ancillary spaces used by performers....
-
Location of accessible routes to stages. (Section-by-Section Analysis)
The 1991 Standards at section 4.33.5 require an accessible route to connect the accessible seating and the stage, as well as other ancillary spaces used by performers....
-
11B-502.5 Vertical clearance
Parking spaces for vans and access aisles and vehicular routes serving them shall provide a vertical clearance of 98 inches (2490 mm) minimum. ...
-
11B-502.5 Vertical clearance
Parking spaces for vans and access aisles and vehicular routes serving them shall provide a vertical clearance of 98 inches (2490 mm) minimum. ...
-
Projecting Authority and Stability in High-Stakes Negotiation Rooms
A neglected meeting space signals structural weakness and a lack of operational control....
-
§382.111(a)
(a) Assistance in moving to and from seats, as part of the enplaning and deplaning processes;...
-
§ 36.406(f)(4)(i)
(i) It is located within the rear 60% of the seats provided in an auditorium; or...
-
§ 35.151(g)(4)(i)
(i) It is located within the rear 60% of the seats provided in an auditorium; or...
-
ACCESS AISLE
[DSA-AC] An accessible space adjacent to or between vehicle spaces that provides clearances in compliance with this code....
-
2013 & 2016 CBC Answer
Based on the attached diagram, the accessible parking and its access aisle are adjacent to another parking space; therefore the width measurement shall be taken from centerline of the markings...
-
II. Terms of Agreement
Such renovation may include the removal of the second-row seating presently in place if feasible....
-
608.5.1 Transfer Type Shower Compartments
In transfer type shower compartments, the controls, faucets, and shower spray unit shall be installed on the side wall opposite the seat 38 inches (965 mm) minimum and 48 inches (1220 mm...
-
§ 36.406(d)(2)
(2) Facilities with more than 50 beds covered by this section that provide common use bathing facilities, shall provide at least one roll in shower with a seat that complies with the relevant...