Floors of amusement rides with wheelchair spaces and floors of load and unload areas shall be coordinated so that, when amusement rides are at rest in the load and unload position, the vertical...
Search Results "Extended Floor Surface"
Commonly Searched Documents
-
1002.4.3 Gaps
-
§ 38.159(d)(2) Location and size
The securement system shall be placed as near to the accessible entrance as practicable and shall have a clear floor area of 30 inches (760 mm) by 48 inches (1220 mm)....
-
5.4.1.2 Transfer and Positioning Support Location for Imaging Equipment
Transfer supports should be provided for imaging equipment with transfer surfaces with depths of less than or equal to 24 inches....
-
1(3)(a)(i)
(i) Where a building elevator is provided only as a means of creating an accessible route to dwelling units on a ground floor, the building is not considered an elevator building for purposes...
-
K4
If built-in food, drink, condiment, and tableware dispensers are provided, are dispensers and operating controls mounted no higher than 54 inches above the floor if clear floor space is...
-
1(3)(a)
(a) There is an elevator connecting the parking area with the dwelling units on a ground floor....
-
Jamb Signage
...are all elevator jambs provided with signs placed on both sides designating the floor with 2" minimum height raised letters and Braille characters centered at 60" above the finish floor...
-
5e.
Are signs mounted on both sides of the elevator hoistway door opening that designate the floor with 2-inch minimum-height raised letters and Braille characters centered at 60 inches above...
-
22. How can I get copies of the ASTM standards that apply to play areas?
American Society for Testing and Materials, 100 Bar Harbor Drive, West Conshohocken, Pennsylvania 19428, www.astm.org: ASTM F 1292-99 Standard Specification for Impact Attenuation of Surface...
-
SEAT HEIGHT MEASUREMENT DETAIL
Note that examination tables and chairs only use bolsters on certain areas of the transfer surface....
-
1.3.2 Focus Following NPRM Comments
This review identified four major issue areas for the MDE Advisory Committee to address, as follows: Transfer surface height and size Permitted obstructions to the transfer surface...
-
IMPLICATION OF A 19-INCH MINIMUM STANDARD FOR THE HIGHEST POINT IN THE LOWEST ADJUSTABLE POSITION
However, shorthand references to 19 inches as the minimum standard as used in this minority report should not be equated with a 19-inch transfer surface height, for two major reasons....
-
Areas for further work
Areas for further work In the process of assisting the various organizations that represent surface materials and professional groups the following issues were identified as parameters...
-
Finish and Contrast: ADA Standard Section 703.7.1
Additional factors affecting the ease with which the text can be distinguished from its background include shadows cast by lighting sources, surface glare, and the uniformity of the text...
-
Finish and Contrast: ADA Standard Section 703.5.1
Additional factors affecting the ease with which the text can be distinguished from its background include shadows cast by lighting sources, surface glare, and the uniformity of the text...
-
WORKSTATION
[DSA-AC] An area defined by equipment and/or work surfaces intended for use by employees only, and generally for one or a small number of employees at a time....
-
11B-703.5.1 Finish and contrast
Additional factors affecting the ease with which the text can be distinguished from its background include shadows cast by lighting sources, surface glare, and the uniformity of the text...
-
11B-703.7.1 Finish and contrast
Additional factors affecting the ease with which the text can be distinguished from its background include shadows cast by lighting sources, surface glare, and the uniformity of the text...
-
11B-703.6.2 Finish and contrast
Additional factors affecting the ease with which the text can be distinguished from its background include shadows cast by lighting sources, surface glare, and the uniformity of the text...
-
11B-407.2.1.2 Size and shape
buttons shall have square shoulders, be ¾ inch (19.1 mm) minimum in the smallest dimension and shall be raised 1/8 inch (3.2 mm) plus or minus 1/32 inch (0.8 mm) above the surrounding surface...
-
11B-407.2.1.5 Signals
Call buttons shall be internally illuminated with a white light over the entire surface of the button. [2010 ADA Standards] 407.2.1.5 Signals....
-
217.2 Wheelchair Accessible Telephones
Table 217.2 Wheelchair Accessible Telephones Number of Telephones Provided on a Floor, Level, or Exterior Site Minimum Number of Required Wheelchair Accessible...
-
5.3.3.3 Location Where Walls Not Provided
Where walls or partitions are not provided, the seat shall be positioned in a corner of the clear floor or ground space required by 5.3.2 for a left-hand or right-hand approach. ...
-
5.3.3.3 Location Where Walls Not Provided
Where walls or partitions are not provided, the seat shall be positioned in a corner of the clear floor or ground space required by 5.3.2 for a left-hand or right-hand approach....