VERTICAL ACCESS Elevators: Controls; visual and audio signals 11B-407.2 Elevators: Symbols 11B-407.4.7.1...
Search Results "Door Control"
-
Vertical Access
-
Vertical Access
VERTICAL ACCESS Elevators: Controls; visual and audio signals 11B-407.2 Elevators: Symbols 11B-407.4.7.1...
-
4.34.5.5(5) Shower unit
Figure 49 Location of Grab Bars and Controls of Adaptable Showers...
-
11B-611.4 Height
Top loading machines shall have the door to the laundry compartment located 36 inches (914 mm) maximum above the finish floor....
-
611.4 Height
Top loading machines shall have the door to the laundry compartment located 36 inches (915 mm) maximum above the finish floor....
-
233.3.6
duplexes, triplexes, condominiums, and townhouses shall provide at least one bathroom, located with maximum possible privacy, where bathrooms are provided on habitable grade levels, with a door...
-
F213.2.1 Unisex (Single-Use or Family) Toilet and Unisex Bathing Rooms
Doors to unisex toilet rooms and unisex bathing rooms shall have privacy latches....
-
213.2.1 Unisex (Single-Use or Family) Toilet and Unisex Bathing Rooms
Doors to unisex toilet rooms and unisex bathing rooms shall have privacy latches....
-
1134A.8, Item 4.3
Doors to the cabinet beneath the lavatory shall be removable or openable to provide the required unobstructed knee and toe space....
-
Section 508
Section508.gov opening doors logo....
-
1134A.8, Item 4.3
Doors to the cabinet beneath the lavatory shall be removable or openable to provide the required unobstructed knee and toe space....
-
§ 38.31(c)
(c) The vehicle doorways, including doorways in which lifts or ramps are installed, shall have outside light(s) which, when the door is open, provide at least 1 foot-candle of illumination...
- Schumacher 1400 Series Limited Use Limited Application (LULA) Elevator
-
E202.4 Functions Located in Maintenance or Monitoring Spaces (Section-by-Section Analysis)
Functions of ICT located in maintenance spaces that can be controlled remotely, however, would still be required to comply with applicable standards....
-
11B-810.2.2 Dimensions
Board's Note to Reader: The Department of Transportation's ADA Standards indicate that compliance is required to the extent construction specifications are within a public entity's control...
-
2. Q: Which child care centers are covered by title III?
Activities controlled by religious organizations are not covered by title III....
-
Hospital and healthcare settings. (Section-by-Section Analysis)
The Department generally follows the guidance of the Centers for Disease Control and Prevention (CDC) on the use of service animals in a hospital setting....
-
6. Exemption for Program Access Improvements
Improvements The City will be exempted from any obligation to perform a Program Access Improvement at a particular location if: There exist barriers to remediation that are controlled...
-
Alternate modes
Different means of providing information to users of products including product documentation and information about the status or operation of controls....
- Panda S.85 All Aluminum Slim Profile Lift & Slide System
- SafePath: ADA Entry Level Landing Installation Training Video
-
11B-405.8 Handrails
At door landings, handrails are not required on ramp runs less than 6 inches (152 mm) in rise or 72 inches (1829 mm) in length....
-
11B-604.3.1 Size
Note The CBC 11B-604.3.1 requirement for maneuvering space in front of accessible water closets exceeds the 2010 ADA Standards requirement for water closet clear floor space, but a door...