A grade of up to 1:10 (10 percent) is permitted for up to 30 feet (9 m) of an ORAR. Resting intervals complying with section 2.3 shall be provided at distances of no more than 30...
Search Results "CCDA: California Commission on Disability Access"
-
2.4.1.3
-
A4.3.1 GENERAL
[See subsections ...]
-
1018.7.2 Cross Slope
The cross slope shall not be steeper than 1:48. EXCEPTION: Where the surface is other than concrete, asphalt, or boards, cross slopes not steeper than 1:20 shall be permitted when...
-
2.4.1.1
The running slope (grade) of an ORAR shall be 1:20 (5 percent) or less for any distance.
-
11B-401 General
[See subsections ...]
-
1.1.8 City, county or city and county amendments, additions or deletions
The provisions of this code do not limit the authority of city, county, or city and county governments to establish more restrictive and reasonably necessary differences to the...
-
§ 37.61 Public transportation programs and activities in existing facilities
[See subsections ...]
-
11B-401 General
[See subsections ...]
-
1.1.8 City, county, or city and county amendments, additions or deletions
The provisions of this code do not limit the authority of city, county, or city and county governments to establish more restrictive and reasonably necessary differences to the...
-
§382.51(b)(2)
(2) You may meet this obligation through any combination of facility accessibility, auxiliary aids, equipment, the assistance of personnel, or other appropriate means consistent with the...
-
B. Ticketing:
the automatic reassignment of the accessible seating to such ticket holders for future seasons so that individuals with disabilities who require the features of accessible seating and who...
-
Surfaces for Outdoor Recreation Access Routes
The surface of an outdoor recreation access route and the surface surrounding constructed features must be firm and stable. No exceptions are allowed....
-
What other voting rights laws does the Justice Department enforce?
10) requires states to make voter registration opportunities for federal elections available through the mail and when people apply for or receive a driver's license, public assistance, disability...
-
Recommendations on Standards for the Design of Medical Diagnostic Equipment for Adults with Disabilities, Advisory Committee Final Report
Advancing Equal Access to Diagnostic Services: Recommendations on Standards for the Design of Medical Diagnostic Equipment for Adults with Disabilities The final report of the Medical...
-
Other Services and Accommodations
◼ Disabled passengers’ items stored in the cabin must conform to FAA rules on the stowage of carry-on baggage....
-
Time periods
Time Periods Paragraphs (c) and (d) establish time periods for complying with the program accessibility requirement....
-
Door King Inc. Seamless Access Control with the DKS 9000 Vehicular Slide Gate Operator
Requires the Registered User plan or above. Login!
- Signaids Men's Washroom Directional Sign
-
1016.1 General
This section contains the technical requirements for outdoor recreation access routes....
-
D. What tools are needed to conduct a survey and how do you use them?
The following are the standard tools that the Civil Rights Division uses in conducting its surveys under Project Civic Access: a metal measuring tape that is at least 25-feet long...
-
604.9.1 Location
maximum from the side wall or partition, except that the water closet shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum from the side wall or partition in the ambulatory accessible...
-
604.9.1 Location
maximum from the side wall or partition, except that the water closet shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum from the side wall or partition in the ambulatory accessible...
-
604.9.1 Location
maximum from the side wall or partition, except that the water closet shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum from the side wall or partition in the ambulatory accessible...
-
11B-604.9.1 Location
maximum from the side wall or partition, except that the water closet shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum from the side wall or partition in the ambulatory accessible...