Where multiple single-user toilet rooms are clustered in a single location, fifty percent (50%), rather than the one hundred percent (100%) required by the 1991 Standards, are required to...
Search Results "One Step Entry"
-
Multiple Single-User Toilet Rooms
-
1009.2.1 Pool Lift Location
Where multiple pool lift locations are provided, no more than one pool lift shall be required to be located in an area where the water level is 48 inches (1220 mm) maximum....
-
§382.83(a)(2)(iii)
You may require such a passenger to check in and request the seating accommodation at least one hour before the standard check-in time for the flight....
-
1. Adoption of the 2010 ADA Standards for Accessible Design
To minimize compliance burdens on entities subject to more than one legal standard, these design standards have been harmonized with the Federal standards implementing the Architectural...
-
1. Adoption of the 2010 ADA Standards for Accessible Design
To minimize compliance burdens on entities subject to more than one legal standard, these design standards have been harmonized with the Federal standards implementing the Architectural...
-
F232.3 Special Holding Cells and Special Housing Cells
Where special holding cells or special housing cells are provided, at least one cell serving each purpose shall provide mobility features complying with 807.2....
-
11B-607.4.2.1 Back wall
Two grab bars shall be installed on the back wall, one located in accordance with Section 11B-609.4 and the other located 8 inches (203 mm) minimum and 10 inches (254 mm) maximum above the...
-
§382.117(e)
., no older than one year from the date of the passenger's scheduled initial flight) on the letterhead of a licensed mental health professional (e.g., psychiatrist, psychologist, licensed...
-
1007.8 Two-way communication
A two-way communication system shall be provided at the elevator landing on each accessible floor that is one or more stories above or below the story of exit discharge complying with Sections...
-
11B-232.3 Special holding cells and special housing cells
Where special holding cells or special housing cells are provided, at least one cell serving each purpose shall provide mobility features complying with Section 11B-807.2....
-
1009.4.1 Clear Deck Space
Where one grab bar is provided, the clear deck space shall be centered on the grab bar....
-
Definition of "Mezzanine"
Mezzanine" is now defined by the same definition used in the IBC: "An intermediate level or levels between the floor and ceiling of any story with an aggregate floor area of not more than one-third...
-
F216.11 Check-Out Aisles
Where more than one check-out aisle is provided, check-out aisles complying with 904.3 shall be identified by the International Symbol of Accessibility complying with 703.7.2.1....
-
707.1 General
If farecards have one tactually distinctive corner they can be inserted with greater accuracy....
-
229.1 General
Where glazed openings are provided in accessible rooms or spaces for operation by occupants, at least one opening shall comply with 309....
-
707.1 General
If farecards have one tactually distinctive corner they can be inserted with greater accuracy....
-
407.4.6.1 Location
Controls shall be located within one of the reach ranges specified in 308. EXCEPTIONS: 1....
-
F225.2.1 Lockers
Where lockers are provided, at least 5 percent, but no fewer than one of each type, shall comply with 811....
-
Unique Attractions
An accessible route should be provided to connect to a reasonable number, but at least one, of these attractions. If appropriate technical provisions exist, they should be applied....
-
607.4.2.1 Back Wall
Two grab bars shall be installed on the back wall, one located in accordance with 609.4 and other located 8 inches (205 mm) minimum and 10 inches (255 mm) maximum above the rim of the bathtub...
-
304.3.2 T-Shaped Space
The space shall be permitted to include knee and toe clearance complying with 306 only at the end of either the base or one arm....
-
Toilet and Bathing Facilities [F213 and 603 through 610]
When bathing facilities are provided, at least one transfer shower, roll-in shower, or accessible bathtub must be provided....
-
407.4.6.1 Location
Controls shall be located within one of the reach ranges specified in 308. EXCEPTIONS: 1....
-
216.11 Check-Out Aisles
Where more than one check-out aisle is provided, check-out aisles complying with 904.3 shall be identified by the International Symbol of Accessibility complying with 703.7.2.1....