An accessible entrance must provide at least one accessible door with maneuvering space, accessible hardware, and enough clear width to allow people who use crutches, a cane, walker, scooter...
Search Results "Clear Ground Space"
Commonly Searched Documents
-
D. Entering the Emergency Shelter
-
11B-203.10 Raised refereeing, judging, and scoring areas
An accessible route complying with Division 4 shall be provided to the ground- or floor-level entry points, where provided, of stairs, ladders, or other means of reaching the raised elements...
-
11B-1009.2.6 Footrests and armrests
The armrest positioned opposite the water shall be removable or shall fold clear of the seat when the seat is in the raised (load) position....
-
Use Zone
The ground level area beneath and immediately adjacent to a play structure or play equipment that is designated by ASTM F 1487 (incorporated by reference, see “Referenced Standards” in Chapter...
-
Length: ADA Standard Section 405.7.3
Section 405.7.3 covers the current ADA Standards for the required length of ramp landings.
-
11B-405.7.3 Length
The landing clear length shall be 60 inches (1524 mm) long minimum....
-
11B-208.2 Minimum number
TABLE 11B-208.2 PARKING SPACES TOTAL NUMBER OF PARKING SPACES PROVIDED IN PARKING FACILITY MINIMUM NUMBER OF REQUIRED ACCESSIBLE PARKING SPACES...
-
11B-208.2 Minimum number
TABLE 11B-208.2 PARKING SPACES Total Number Of Parking Spaces Provided In Parking Facility Minimum Number Of Required Accessible Parking Spaces 1 to...
-
1134A.7 Water closets
Floor space and location. The minimum floor space provided at a water closet shall be 48 inches (1219 mm) in clear width. ...
-
Salsbury Industries 66016 Standard Metal Locker with Box Style Bridge
Requires the Registered User plan or above. Login!
-
Width: ADA Standard Section 405.7.2
Section 405.7.2 covers the current ADA Standards for the required width of ramp landings.
-
11B-405.7.2 Width
The landing clear width shall be at least as wide as the widest ramp run leading to the landing....
-
11B-219.5 Permanent and portable systems
The California Building Code (CBC) requires permanently installed assistive listening systems in those assembly areas where audible communication is integral to the use of a space (movie...
-
What do I do if I believe that carriage of the animal in the cabin of the aircraft would inconvenience non-disabled passengers?
., a cultural or personal discomfort with being in proximity to certain kinds of animals, allergies that do not rise to the level of a disability, reasonable limitations on foot space) is...
-
11B-233.3.1.2.4 Multi-story residential dwelling units
housing facilities with multi-story residential dwelling units shall comply with the following: Exception: In non-elevator buildings, a minimum of 10 percent but not less than one of the ground...
-
Scoping [4.1.2(6), 4.1.3(11)]
(In multi-story buildings exempt from the elevator requirement, toilet/ bathing facilities are required on the accessible ground floor if provided on other floors.)...
- M-Dura Modern Suite | Moen Features Spotlight
-
Handrails
If handrails are mounted on walls, the clear space between the handrail and wall must be 1.5 inches....
-
308.2.2 Obstructed High Reach
Where a high forward reach is over an obstruction, the clear floor space shall extend beneath the element for a distance not less than the required reach depth over the obstruction....
-
Openings [1018.6]
Gaps, including spaces between the planks on a boardwalk and drainage holes in temporary or permanent surfaces, that are big enough for wheels, canes, or crutch tips to drop through or become...
-
R212 Street Furniture (Section-by-Section Analysis)
At least 50 percent, but no less than one, of benches at each location must provide a clear space for a wheelchair adjacent to the bench. Benches at tables are not required to comply....