attached to land) are involved, a number of exceptions are provided from the general standards for accessible routes in order to take into account the difficulty of meeting accessibility slope...
Search Results "Sloped Area"
-
Boating facilities. (Section-by-Section Analysis)
-
407.12.3.2.2 Knee and Toe Space (Section-by-Section Analysis)
Building on this exception, the second exception would allow further reduction in the height of the space along the profile of the knee to the toe sloping at 6:1 toward the maximum protrusion...
-
4.9.4 HANDRAILS
At the bottom, the handrail shall continue to slope for a distance of the width of one tread from the bottom riser; the remainder of the extension shall be horizontal (see Fig. 19(c) and...
-
Standardized Tests of Physical Fitness and Community Ambulation
Perceived difficulty was designed to consider factors such as the security of footing, obstacle negotiation, and effort required on slopes....
-
11B-233.3.1.2.6.1 Single building with one common (lobby) entrance
Test No. 1 -- Individual Building Test may only be used if the site has terrain over 15 percent slope. Test No. 3 -- Unusual Characteristics Test may be used if applicable....
-
3. Camera
Consider taking additional photos of the digital level showing slope and cross slope measurements of walkways and ramps as well as photos showing exactly where the digital level was placed...
-
Clear Ground Space [1011.2]
The technical requirements include specific provisions for the size, location, surface, slope, and openings in the clear ground space....
-
A) Accessible Parking
Access aisle of at least 60-inch width must be level (1:50 maximum slope in all directions), be the same length as the adjacent parking space(s) it serves and must connect to an accessible...
-
II. Rulemaking History
The 2007 draft also proposed to decrease the maximum running slope of vehicle ramps to 1:8 (as compared to the existing guidelines, which specify a range of ramp slopes from 1:4 to 1:12,...
-
Ticket Prices and Dispersal of Wheelchair Spaces
Paragraph 5 of the "Line of Sight and Dispersion of Wheelchair Spaces in Assembly Areas" section of the Department of Justice's Guidance on the 2010 ADA Standards for Accessible Design document...
- ADA25: #17 of 25 -- Recreation
-
11B-804.2.2 U-Shaped
In U-shaped kitchens enclosed on three contiguous sides, clearance between all opposing base cabinets, counter tops, appliances, or walls within kitchen work areas shall be 60 inches (1524...
-
§ 36.406(f)(4)(ii)
(ii) It is located within the area of an auditorium in which the vertical viewing angles (as measured to the top of the screen) are from the 40th to the 100th percentile of vertical viewing...
-
11B-203.14 Raised diving boards and diving platforms
accessible route complying with Division 4 shall be provided to the ground- or floor-level entry points, where provided, of stairs, ladders, or other means of reaching the raised elements or areas...
-
1002 Amusement Rides
This section also addresses access at loading and unloading areas and provides criteria for wheelchair spaces, ride seats designed for transfer, and transfer devices....
-
505.3 Continuity
EXCEPTION: In assembly areas, handrails on ramps shall not be required to be continuous in aisles serving seating....
-
Maps/floor plans
at the front desk for use during the Museum visit an up-to-date tactile map of the Museum's current floor plan, including temporary exhibitions, changes to the permanent exhibition and areas...
-
Common Technical Requirements
For instance, if five benches are provided at a viewing area, at least 20 percent (or one) of the benches must comply with the technical requirements for benches....
-
505.3 Continuity
EXCEPTION: In assembly areas, handrails on ramps shall not be required to be continuous in aisles serving seating....
-
§ 36.406(f)(4)(ii)
(ii) It is located within the area of an auditorium in which the vertical viewing angles (as measured to the top of the screen) are from the 40th to the 100th percentile of vertical viewing...
-
11B-608.6 Shower spray unit and water
Corrects prior drafting error by limiting the types of facilities that are allowed to use the vandalism prone area exception and requiring one of the two shower heads to be a maximum of...
-
§ 35.151(g)(4)(ii)
(ii) It is located within the area of an auditorium in which the vertical viewing angles (as measured to the top of the screen) are from the 40th to the 100th percentile of vertical viewing...
-
§ 37.42(e)(2)
mini-high platform or where the physical structure of an existing station does not allow such clearance), barriers must be used to prevent the flow of pedestrian traffic through these narrower areas...
-
505.3 Continuity
EXCEPTION: In assembly areas, handrails on ramps shall not be required to be continuous in aisles serving seating....