Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the seat, fastener, mounting device, or...
Search Results "Vertical Rod"
-
11B-903.6 Structural strength
-
11B-903.6 Structural strength
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the seat, fastener, mounting device, or...
- PEMKO 5" Latching Panic Saddle Threshold No. 2006-P
- PEMKO 4" Latching Panic Saddle Threshold No. 278x224-FGT
- PEMKO 5" Latching Panic Saddle Threshold No. 2006-V
-
Housekeeping
Ensure the shower head is placed at its lowest level on the rod. Ensure toiletry items are placed within reach limits for those with limited reach range....
- AJW Architectural Products U126 40 oz. Vertical Liquid Soap Dispenser - Surface Mounted
- AJW Architectural Products U155 24 oz. Vertical Liquid Soap Dispenser - Surface Mounted
- CRL Jackson 1200 Series Push Pad Door Exit Devices
- PEMKO 5" Latching Panic Saddle Threshold No. 2005-V
- PEMKO 5" Latching Panic Saddle Threshold No. 2005-P
-
11B-221.2.1.5 Stadium-style movie theaters
satisfy at least one of the following criteria: Located within the rear 60 percent of the seats provided in the theater; or Located within the area of the theater in which the vertical...
-
11B-221.2.1.5 Stadium-style movie theaters
satisfy at least one of the following criteria: Located within the rear 60 percent of the seats provided in the theater; or Located within the area of the theater in which the vertical...
-
1015.3 Height
Required guards shall not be less than 42 inches (1067 mm) high, measured vertically as follows: From the adjacent walking surfaces....
-
1015.3 Height
Required guards shall not be less than 42 inches (1067 mm) high, measured vertically as follows: From the adjacent walking surfaces....
- Allegion Von Duprin 98/99 Series Von Duprin CVC Traditional and Quick Adjust Bottom Latch Adjustment
-
RAMP
A walking surface that has a running slope steeper than one unit vertical in 20 units horizontal (5-percent slope)....
-
RAMP
A walking surface that has a running slope steeper than one unit vertical in 20 units horizontal (5-percent slope)....
- Corbin Russwin Inc. ED3000 Series Crossbar Exit Device
- PEMKO 5" Latching Panic Saddle Threshold No. 2006-T
- PEMKO 5" Latching Panic Saddle Threshold No. 2005-T
- PEMKO 5 5/16" Latching Panic Saddle Threshold No. 273x224-FGT
-
Re: How to Use the Pressure Gauge Tool
It appeared that the labels on the measuring rods were shifted one pound off. Whichever type of tool you use, try to find a way to verify that it's accurate....
-
11B-411.2.1.4.1.1 Arrangement
Buttons shall be arranged in columns to the right of the keypad with a minimum horizontal spacing of 1.5 times the horizontal spacing between the numeric keys and with the same vertical...