Sections 11B-809.2 through 11B-809.4, and adaptable features complying with Sections 11B-809.6 through 11B-809.12 parking spaces provided in accordance with Section 11B-208.2.3.1 shall be located...
Search Results "Securement Location"
-
11B-208.3.2 Residential facilities
-
F208.3.1 General
Parking spaces complying with 502 that serve a particular building or facility shall be located on the shortest accessible route from parking to an entrance complying with F206.4....
- Access Board: How People with Low Vision or Blindness Approach Tactile Signs
-
Is there a maximum travel distance to entrances from parking and other site arrival points?
Accessible parking spaces must be located on the shortest accessible route to an accessible entrance (relative to other spaces in the parking facility)....
-
10.3.1(6)
(6) Lists of stations, routes, or destinations served by the station and located on boarding areas, platforms, or mezzanines shall comply with 4.30.1, 4.30.2, 4.30.3, and 4.30.5....
-
602.6 Water Flow
The spout shall provide a flow of water 4 inches (100 mm) high minimum and shall be located 5 inches (125 mm) maximum from the front of the unit....
-
602.6 Water Flow
The spout shall provide a flow of water 4 inches (100 mm) high minimum and shall be located 5 inches (125 mm) maximum from the front of the unit....
-
602.6 Water Flow
The spout shall provide a flow of water 4 inches (100 mm) high minimum and shall be located 5 inches (125 mm) maximum from the front of the unit....
-
11B-602.6 Water flow
The spout shall provide a flow of water 4 inches (102 mm) high minimum and shall be located 5 inches (127 mm) maximum from the front of the unit....
-
11B-602.6 Water flow
The spout shall provide a flow of water 4 inches (102 mm) high minimum and shall be located 5 inches (127 mm) maximum from the front of the unit....
-
11B-602.6 Water flow
The spout shall provide a flow of water 4 inches (102 mm) high minimum and shall be located 5 inches (127 mm) maximum from the front of the unit....
-
11B-604.5.1 Side wall
The side wall grab bar shall be 42 inches (1067 mm) long minimum, located 12 inches (305 mm) maximum from the rear wall and extending 54 inches (1372 mm) minimum from the rear wall with...
-
11B-604.5.1 Side wall
The side wall grab bar shall be 42 inches (1067 mm) long minimum, located 12 inches (305 mm) maximum from the rear wall and extending 54 inches (1372 mm) minimum from the rear wall with...
-
11B-216.2 Designations
Exception: Exterior signs that are not located at the door to the space they serve shall not be required to comply with Section 11B-703.2....
-
11B-216.2 Designations
Exception: Exterior signs that are not located at the door to the space they serve shall not be required to comply with Section 11B-703.2....
-
Position of Grab Bars: ADA Standard Section 609.4
Section 609.4 covers the current ADA Standards for the position of grab bars.
-
11B-609.4 Position of grab bars
Grab bars shall be installed in a horizontal position, 33 inches (838 mm) minimum and 36 inches (914 mm) maximum above the finish floor measured to the top of the gripping surface,...
-
11B-609.4 Position of grab bars
Grab bars shall be installed in a horizontal position, 33 inches (838 mm) minimum and 36 inches (914 mm) maximum above the finish floor measured to the top of the gripping surface,...
-
11B-604.5.1 Side wall
The side wall grab bar shall be 42 inches (1067 mm) long minimum, located 12 inches (305 mm) maximum from the rear wall and extending 54 inches (1372 mm) minimum from the rear wall with...
-
6.14.1 Clear Width
Gate openings and openings in barriers for pedestrian passage shall provide a clear width of 36 inches (915 mm), complying with ODAAG, section 1017.3 Clear Tread Width.
- University of Michigan Transportation Research Institute