Where food or drink is served for consumption at a counter exceeding 34 inches (864 mm) in height, a portion of the main counter 60 inches (1525 mm) minimum in length shall be...
Search Results "Salad Bar"
Commonly Searched Documents
-
11B-226.3 Dining surfaces exceeding 34 inches in height
-
11B-226.3 Dining surfaces exceeding 34 inches in height
Where food or drink is served for consumption at a counter exceeding 34 inches (864 mm) in height, a portion of the main counter 60 inches (1525 mm) minimum in length shall be...
-
Grab Bars [4.20.4] and Controls [4.20.5]
Grab Bars [4.20.4] and Controls [4.20.5] Controls must be within reach from outside the tub and cannot interfere with the use of the grab bars....
-
Note
Note: Grab bars can be designed so they do not increase suicide risk....
-
Kitchens, Kitchenettes, or Wet Bars [9.2.2(7)]
Kitchens, Kitchenettes, or Wet Bars [9.2.2(7)] Clear floor space for either a forward or a side approach is permitted for cabinets, counters, sinks, and appliances....
-
11B-609.2.2 Non-circular cross section
Grab bars with non-circular cross sections shall have a cross-section dimension of 2 inches (51 mm) maximum and a perimeter dimension of 4 inches (102 mm) minimum and 4.8 inches (122 mm)...
-
609.2.2 Non-Circular Cross Section
Grab bars with non-circular cross sections shall have a cross-section dimension of 2 inches (51 mm) maximum and a perimeter dimension of 4 inches (100 mm) minimum and 4.8 inches (120 mm)...
-
609.2.2 Non-Circular Cross Section
Grab bars with non-circular cross sections shall have a cross-section dimension of 2 inches (51 mm) maximum and a perimeter dimension of 4 inches (100 mm) minimum and 4.8 inches (120 mm)...
-
36 Inch Wide Stalls
A 36-inch width (absolute) allows the parallel grab bars to be used simultaneously when changing from a standing position to a seated position and vice versa....
-
§301(7)(B)
A restaurant, bar, or other establishment serving food or drink;...
-
12181(7)(B)
(B) a restaurant, bar, or other establishment serving food or drink;...
-
11B-809.10.7.3 Reinforcement for grab bars
Reinforcement for grabs bars shall comply with the following: Where water closets are not placed adjacent to a side wall capable of accommodating a grab bar, the bathroom shall...
- Figure 604.5.2 Rear Wall Grab Bar at Water Closets – Drawing from the U.S. Access Board
-
11B-604.7 Dispensers and disposal units
The outlet of the dispenser shall be 15 inches (380 mm) minimum and 48 inches (1220 mm) maximum above the finish floor and shall not be located behind grab bars....
-
609.2.2 Non-Circular Cross Section
Grab bars with non-circular cross sections shall have a cross-section dimension of 2 inches (51 mm) maximum and a perimeter dimension of 4 inches (100 mm) minimum and 4.8 inches (120 mm)...
-
609.2.2 Non-Circular Cross Section
Grab bars with non-circular cross sections shall have a cross-section dimension of 2 inches (51 mm) maximum and a perimeter dimension of 4 inches (100 mm) minimum and 4.8 inches (120 mm)...
-
11B-609.2.2 Non-circular cross section
Grab bars with non-circular cross sections shall have a cross-section dimension of 2 inches (51 mm) maximum and a perimeter dimension of 4 inches (102 mm) minimum and 4.8 inches (122 mm)...
-
Error/Omission: Toilet rooms with 6 or more toilet stalls lack a 36" wide "ambulatory" toilet stall.
People who walk with crutches, a cane, a walker, or who have limited balance generally find it easier and safer to use a stall that has parallel grab bars....
-
11B-609.2.2 Non-circular cross section
Grab bars with non-circular cross sections shall have a cross-section dimension of 2 inches (51 mm) maximum and a perimeter dimension of 4 inches (102 mm) minimum and 4.8 inches (122 mm)...
-
Clear Deck Space
If there is one grab bar on a transfer wall, the clear deck space must be centered on the one grab bar. That allows enough space for a transfer on either side of the bar....
-
1134A.6, Item 4
Reinforced walls for grab bars. Grab bar reinforcement shall be installed continuous in the walls of showers 32 inches to 38 inches (813 mm to 965 mm) above the floor....
-
1009.4.1 Clear Deck Space
Where one grab bar is provided, the clear deck space shall be centered on the grab bar....
-
1134A.6, Item 4