A recipient may not adopt or maintain a system for admission to a secondary vocational education center or program that limits admission to a fixed number of students from each sending school...
Search Results "Protrusion Limit"
-
F. Eligibility for Admission to Secondary Vocational Education Centers Based on Numerical Limits Imposed on Sending Schools
-
Section 1630.2(j)(1)(ix) Effects of an Impairment Lasting Fewer Than Six Months Can Be Substantially Limiting
Section 1630.2(j)(1)(ix) Effects of an Impairment Lasting Fewer Than Six Months Can Be Substantially Limiting Section 1630.2(j)(1)(ix) states: “The six-month ‘transitory' part of the...
-
QUESTION: MAY PVOs ESTABLISH POLICIES PROHIBITING OR LIMITING PASSENGERS WITH DISABILITIES FROM TRAVELING WITH ANIMALS?
39.3, 39.21(b), 39.91 QUESTION: MAY PVOs ESTABLISH POLICIES PROHIBITING OR LIMITING PASSENGERS WITH DISABILITIES FROM TRAVELING WITH ANIMALS?...
-
§ 1194.25(j)(1)
(1) The position of any operable control shall be determined with respect to a vertical plane, which is 48 inches in length, centered on the operable control, and at the maximum protrusion...
-
Can the carrier limit the amount of money they pay me for this claim...as they currently may for domestic baggage claims?
Can the carrier limit the amount of money they pay me for this claim to $2,800, as they currently may for domestic baggage claims? ANSWER: No....
-
407.8.3.2 Obstructed Forward Reach
Where the operable part is located beyond the leading edge of the maximum protrusion within the length of the vertical reference plane, the operable part shall conform to 407.8.3.2....
-
§ 36.302(f)(5)(i) Tickets for accessible seating may be released for sale in certain limited circumstances
(i) Tickets for accessible seating may be released for sale in certain limited circumstances. ...
-
407.8.3.1 Unobstructed Forward Reach
Where the operable part is located at the leading edge of the maximum protrusion within the length of the vertical reference plane of the ICT, the operable part shall be 48 inches (1220...
-
Section 1630.2(j)(1)(iii) Substantial Limitation Should Not Be Primary Object of Attention; Extensive Analysis Not Needed
Section 1630.2(j)(1)(iii) Substantial Limitation Should Not Be Primary Object of Attention; Extensive Analysis Not Needed Section 1630.2(j)(1)(iii) states: “The primary object of attention...
-
407.12.3.2 Obstructed Forward Reach
Where the operable part is located beyond the leading edge of the maximum protrusion within the length of the vertical reference plane, the operable part shall conform to 407.12.3.2....
-
B.1.i. - Is EIT limited to products?
No. EIT, like IT, also includes services. For example, some agencies seek to satisfy their desktop computing needs through so-called "seat management" service contracts. Under a seat...
-
Are requirements for protruding objects limited to hallways and corridors?
No, requirements for protruding objects apply to all circulation paths, including those in rooms and spaces off corridors. They apply to both interior and exterior circulation paths.
-
407.12.3.1 Unobstructed Forward Reach
Where the operable part is located at the leading edge of the maximum protrusion within the length of the vertical reference plane of the ICT, the operable part shall be 48 inches (1220...
-
§ 36.105(d)(2)(iii)(I) Epilepsy, muscular dystrophy, and multiple sclerosis each substantially limits neurological function
(I) Epilepsy, muscular dystrophy, and multiple sclerosis each substantially limits neurological function;...
-
Implementation Challenges for Interiors (slides 16 and 17)
Prescriptive requirements are great, [if they are] backed by research, but that also may limit the design creativity and options and force someone to design something somewhere that may...
-
§ 38.23(c)(2) Ramp surface
The ramp surface shall be continuous and slip resistant; shall not have protrusions from the surface greater than 1/4 inch high; shall have a clear width of 30 inches; and shall accommodate...
-
§ 38.83(c)(2) Ramp surface
The ramp or bridge plate surface shall be continuous and slip resistant, shall not have protrusions from the surface greater then 1/4 inch, shall have a clear width of 30 inches, and shall...
-
§ 38.95(c)(2) Ramp surface
The ramp or bridge plate surface shall be continuous and slip resistant, shall not have protrusions from the surface greater than 1/4 inch high, shall have a clear width of 30 inches and...
-
§ 38.125(c)(2) Ramp surface
The ramp or bridge plate surface shall be continuous and slip resistant, shall not have protrusions from the surface greater than 1/4 inch high, shall have a clear width of 30 inches and...
-
Limited instances in which an accompanying individual may interpret. (Section-by-Section Analysis)
Section 36.303(c)(3) codifies the Department's policy that there are very limited instances when a public accommodation may rely on an accompanying individual to interpret or facilitate...
-
§ 38.159(c)(2) Ramp surface
The ramp surface shall be continuous and slip resistant; shall not have protrusions from the surface greater than 1/4 inch (6.5 mm) high; shall have a clear width of 30 inches (760 mm);...
-
11B-805.7 Built-in cabinets and work surfaces
Wall-mounted units shall comply with protrusion limits prescribed in Section 11B-307.2....
-
11B-805.7 Built-in cabinets and work surfaces
Wall-mounted units shall comply with protrusion limits prescribed in Section 11B-307.2....
-
604.5 Grab Bars
In detention or correction facilities, grab bars shall not be required to be installed in housing or holding cells that are specially designed without protrusions for purposes of suicide...