-
Federal Documents > Standards > 36 CFR Part 1195 Standards for Accessible Medical Diagnostic Equipment
M303 Diagnostic Equipment Used by Patients Seated in a Wheelchair
-
Rulemaking Process Documents > NPRMS > 36 CFR Part 1195 Proposed Accessibility Standards for Medical Diagnostic Equipment NPRM
M303 Diagnostic Equipment Used by Patients Seated in a Wheelchair
-
Federal Documents > Preamble to Guidelines > 36 CFR Parts 1190 and 1191 ADA and ABA Accessibility Guidelines - Preamble (Discussion of Comments and Changes)
224 Transient Lodging Guest Rooms
The minimum number of guest rooms required to be accessible in transient lodging facilities is covered in section 224....
-
Federal Documents > Regulations > 28 CFR Part 36 Nondiscrimination on the Basis of Disability by Public Accommodations and in Commercial Facilities (2010 ADA Title III Regulations with amendments issued through Dec. 2016)
§ 36.406(c)(1) Guest rooms
(1) Guest rooms. Guest rooms with mobility features in places of lodging subject to the transient lodging requirements of 2010 Standards shall be provided as follows –...
-
State and Local Documents > Codes and Standards > 2022 California Standards
11B-224.8.1 More than 25-bed sleeping rooms
In sleeping rooms with more than 25 beds, a minimum of 5 percent of the beds shall have clear floor space complying with Section 11B-806.2.3....
-
Links > Publication
AIA White Paper: A Proposal for additions to accessibility Standards for Nursing Home & Assisted Living Residents in Toileting and Bathing
The bathing/showering area, proposed changes would enable supportive design options in a cost-effective way, so that more buildings could be constructed with a shower in the resident’ room...
-
State and Local Documents > Codes and Standards > 2022 California Standards
11B-803.6 Mirrors
Mirrors shall be installed with the bottom edge of the reflecting surface 20 inches (508 mm) maximum above the finish floor or ground. Mirrors shall be full length with a reflective...
-
State and Local Documents > Codes and Standards > 2019 California Standards
11B-809.10 Toilet and bathing rooms
-
State and Local Documents > Codes and Standards > 2012 Florida Accessibility Code
806 Transient Lodging Guest Rooms
806 Transient Lodging Guest Rooms...
-
Rulemaking Process Documents > NPRMS > 36 CFR Part 1195 Proposed Accessibility Standards for Medical Diagnostic Equipment NPRM - Preamble
4. Organization of Technical Criteria
Medical diagnostic equipment is typically designed to support patients in certain positions....
-
Rulemaking Process Documents > Committee Activity and Reports > Recommendations on Standards for the Design of Medical Diagnostic Equipment for Adults with Disabilities, Advisory Committee Final Report
6. Transfer Surface Height
Given that diagnostic imaging tables are in integral part of the exam and required for accurate results, their design to support very heavy patients, and in some types the existence of imaging...
-
Rulemaking Process Documents > Committee Activity and Reports > Recommendations on Standards for the Design of Medical Diagnostic Equipment for Adults with Disabilities, Advisory Committee Final Report
5.8 Wheelchair Spaces for Diagnostic Equipment Used by Patients Seated in a Wheelchair
5.8 Wheelchair Spaces for Diagnostic Equipment Used by Patients Seated in a Wheelchair....
-
Rulemaking Process Documents > Committee Activity and Reports > Recommendations on Standards for the Design of Medical Diagnostic Equipment for Adults with Disabilities, Advisory Committee Final Report
How to Measure Transfer Surface Height
Many medical examination rooms are equipped with fixed height examination tables, with a typical 32-inch seat height....
-
Rulemaking Process Documents > Committee Activity and Reports > Recommendations on Standards for the Design of Medical Diagnostic Equipment for Adults with Disabilities, Advisory Committee Final Report
M301.2.1 Transfer Surface Height
Additionally these magnetic fields also preclude use of a patient’s mobility device in the exam room....
-
Federal Documents > Preamble to Guidelines > 36 CFR Parts 1190 and 1191 ADA and ABA Accessibility Guidelines - Preamble (Discussion of Comments and Changes)
Number of Accessible Guest Rooms
A hotel and motel trade group opposed any increase in the number of guest rooms required to be accessible and submitted a study it commissioned on the usage of such rooms....
-
Rulemaking Process Documents > Committee Activity and Reports > Recommendations on Standards for the Design of Medical Diagnostic Equipment for Adults with Disabilities, Advisory Committee Final Report
5.7.1.1 Lift Compatibility Clearance in Base for Stretchers (M301)
with a shorter wheelbase than “standard,” the clearance for a lift may use both the clearance in the base and the clearance around the base to position the lift around the stretcher for patient...
-
Rulemaking Process Documents > Committee Activity and Reports > Recommendations on Standards for the Design of Medical Diagnostic Equipment for Adults with Disabilities, Advisory Committee Final Report
M305.2 Transfer Supports
M305.2 Transfer Supports
M305.2.2 Transfer Supports Structural Strength
Proposed requirement:
Transfer supports and their connections shall be capable of resisting vertical...
-
Rulemaking Process Documents > Committee Activity and Reports > Recommendations on Standards for the Design of Medical Diagnostic Equipment for Adults with Disabilities, Advisory Committee Final Report
5.9 Standing Support Recommendations for M304 Diagnostic Equipment Used by Patients in a Standing Position
5.9 Standing Support Recommendations for M304 Diagnostic Equipment Used by Patients in a Standing Position
Description: Many people who ambulate with a disability need support to maintain...
-
Webinars, Videos, and Training > Product Demonstration or Information
Guldmann GH3 Ceiling Lift - Horizontal Lifting
How to use Guldmann GH3 ceiling lift system for horizontal lifting. Read more at http://www.guldmann.net/ceiling-lifts. Watch more videos on http://www.youtube.com/vguldmann
-
Webinars, Videos, and Training > Product Demonstration or Information
Intensive Care Transfer with GH3 Ceiling Lift
Read more about Guldmann ceiling lifts at http://www.guldmann.net/ceiling-lifts
Watch more videos on http://www.youtube.com/vguldmann
-
Webinars, Videos, and Training > Product Demonstration or Information
Guldmann GH3 Ceiling Lift System
How to use the Guldmann GH3 ceiling lift. Read more at http://www.guldmann.net/ceiling-lifts. Watch more videos on http://www.youtube.com/vguldmann
-
Webinars, Videos, and Training > Product Demonstration or Information
Guldmann GLS 5 Mobile Lifter - Instruction Video
Instruction in how to use the Guldmann GLS 5 Active Lifter (sit-to-stand lifter). The video is showing use with Standing Sling and use with Standing Sling and Hip Sling.
-
Webinars, Videos, and Training > Product Demonstration or Information
Guldmann Mobile Lifter GL5: Lifting from bed to wheelchair
For more information please go to: www.guldmann.com
-
Webinars, Videos, and Training > Product Demonstration or Information
Intensive Care Repositioning with GH3 Ceiling Lift and Turner Sling
Read more about Guldmann ceiling lifts at http://www.guldmann.net/ceiling-lifts
Watch more videos on http://www.youtube.com/vguldmann