The maximum running slope of ramps and bridgeplates shall comply with T402.8.1 or T402.8.2....
Search Results "Counter Slope"
-
T402.8 Running Slope
-
11B-406.2.1 Slope
Ramp runs shall have a running slope not steeper than 1:12....
-
11B-406.2.1 Slope
Ramp runs shall have a running slope not steeper than 1:12....
-
11B-406.2.1 Slope
Ramp runs shall have a running slope not steeper than 1:12....
-
F227.5 Queues and Waiting Lines
Queues and waiting lines servicing counters or check-out aisles required to comply with 904.3 or 904.4 shall comply with 403....
-
227.5 Queues and Waiting Lines
Queues and waiting lines servicing counters or check-out aisles required to comply with 904.3 or 904.4 shall comply with 403....
-
F2
If there is a built-in reception or other type of counter, does it have a section that is at least three feet long that is no higher than 36 inches above the floor or is there a nearby surface...
-
227.5 Queues and Waiting Lines
Queues and waiting lines servicing counters or check-out aisles required to comply with 904.3 or 904.4 shall comply with 403....
-
11B-227.5 Queues and Waiting Lines
Queues and waiting lines servicing counters or check-out aisles required to comply with Sections 11B-904.3 or 11B-904.4 shall comply with Section 11B-403....
-
Surface, Slope, and Openings [1011.2.2, 1011.2.3, and 1011.2.4]
When the surface of the clear ground space is constructed of concrete, asphalt, or boards, the slope of the clear ground space must be no steeper than 1:48 (2 percent) in any direction....
-
Kitchen Counters, Walls, and Floors
Light colored counters and floors throughout to increase reflected light and save energy....
-
Visiting Areas: ADA Standard Section 231.4
Section 231.4 covers scoping requirements in the current ADA Standards for visiting areas.
-
11B-231.4 Visiting areas
Visiting areas shall comply with Section 11B-231.4.
-
11B-231.4 Visiting areas
Visiting areas shall comply with Section 11B-231.4.
-
1.1.4
1.1.4 A maximum overall design running slope for exterior accessible ramps of 7.5% (1:13.3 or 1:13) is recommended....
-
5.1.2 Level or Sloped Entry
Camp shelters providing roll-in access shall have a level or sloped entry that complies with the FSORAG Outdoor Recreation Access Route technical provisions if the camp shelter is in a campground...
-
11B-227.5 Queues and Waiting Lines
Queues and waiting lines servicing counters or check-out aisles required to comply with Sections 11B-904.3 or 11B-904.4 shall comply with Section 11B-403 _|Walking Surfaces|_. ...
-
11B-227.5 Queues and Waiting Lines
Queues and waiting lines servicing counters or check-out aisles required to comply with Sections 11B-904.3 or 11B-904.4 shall comply with Section 11B-403 _|Walking Surfaces|_. ...
-
Cross Slope [1016.7.2]
Cross slope is the side-to-side slope of the surface of an ORAR....
-
Sloped Surfaces
One is the running slope that runs parallel to the direction of travel and the other is the cross slope, which runs perpendicular to the running slope....
-
1.1.6 Flatness of walk cross slope
1.1.6 Flatness of walk cross slope....
-
4.1.6(3)(a)(ii)
(ii) A slope between 1:8 and 1:10 is allowed for a maximum rise of 3 inches. A slope steeper than 1:8 is not allowed....