11B-706.6 Peak clipping level. Peak clipping shall not exceed 18 dB of clipping relative to the peaks of speech....
Search Results "Changes in Level"
Commonly Searched Documents
-
11B-706.6 Peak clipping level
-
2. Electronic (Digital) Level
Even experts can misjudge how steep a running slope or cross slope is if they do not use a level....
- 305.3, 902.1 and 902.2 Baby Changing Table Clear Floor Space
-
11B-206.2.17.1 Ground level and elevated play components
The accessible route shall connect ground level play components required to comply with Section 11B-240.2.1 and elevated play components required to comply with Section 11B-240.2.2, including...
-
11B-813.2.12 Signs
A room identification sign complying with Section 11B-216 shall be provided at entrances to adult changing facilities....
-
11B-813.2.1.5 Obstructions
When deployed, changing tables shall not obstruct the required width of an accessible route except as allowed by Section 11B-307.2....
-
Dispersion
Dispersion Baby changing tables must be dispersed throughout a space based on TAS 226.2, however, an additional baby changing table is not required in a common use area of a toilet or...
-
1008.2.5.1 Ground Level
1008.2.5.1 Ground Level. Ramp runs connecting ground level play components shall have a running slope not steeper than 1:16....
-
11B-408.4.4 Leveling
Elevator car leveling shall comply with Section 11B-407.4.4....
-
11B-408.4.4 Leveling
Elevator car leveling shall comply with Section 11B-407.4.4....
-
11B-408.4.4 Leveling
Elevator car leveling shall comply with Section 11B-407.4.4....
-
11B-813.2.1.3 Height and operation
Adult changing table height shall be adjustable from 17 inches (432 mm) above the floor or ground to 38 inches (965 mm) above the floor or ground, as measured to the top of the changing...
-
1008.2.5.1 Ground Level
Ramp runs connecting ground level play components shall have a running slope not steeper than 1:16....
-
1008.2.5.1 Ground Level
Ramp runs connecting ground level play components shall have a running slope not steeper than 1:16....
-
6. Where multiple swings in a swing bay are provided, Section 240.2.1.1 (one of each type) requires one swing to be located on an accessible route. If an accessible route is provided to more than one swing, can each swing be counted as an accessible ground level play component? If one is an infant seat and another a sling seat, are those considered two different types?
If an accessible route is provided to more than one swing, can each swing be counted as an accessible ground level play component?...
- 902.2 Baby Changing Table Knee Clearance
-
11B-813.2.5 Coat hook
No fewer than one coat hook shall be provided in close proximity to the changing table and within one of the reach ranges specified in Section 11B-308....
-
Maximum Slope at Ground Level
Maximum Slope at Ground Level The maximum allowable slope for a ground-level accessible route is 1:16. Berms are sometimes used to provide access to elevated play areas....
-
11B-813.2.6 Shelf
No fewer than one shelf shall be provided in close proximity to the changing table at 40 inches (1016 mm) minimum and 48 inches (1219 mm) maximum above the finish floor....
-
4. Assess During the Planning, Installation and Maintenance Phases
A tape measure can be used to check any changes in level and openings on the accessible route....
- 902.3 Baby Changing Table Work Surface Height
-
11B-1008.2.5.1 Ground level
Ramp runs connecting ground level play components shall have a running slope not steeper than 1:16....
-
11B-1008.2.5.1 Ground level
Ramp runs connecting ground level play components shall have a running slope not steeper than 1:16....