The transition from roadway or sidewalk and the transition from vehicle floor to the ramp may be vertical without edge treatment up to 1/4 inch (6.5 mm)....
Search Results "Ground Floor Exit"
Commonly Searched Documents
-
§ 38.159(c)(3) Ramp threshold
-
§ 38.95(c)(3) Ramp threshold
The transition from station platform to the ramp or bridge plate and the transition from car floor to the ramp or bridge plate may be vertical without edge treatment up to 1/4 inch....
-
11B-604.9.5 Flush controls
Hand operated flush controls shall comply with Sections 11B-309.2 and 11B-309.4 and shall be installed 36 inches (914 mm) maximum above the finish floor....
-
11B-608.5.1 Transfer type shower compartments
compartments, the controls, faucets, and shower spray unit shall be installed on the side wall opposite the seat 38 inches (965 mm) minimum and 48 inches (1219 mm) maximum above the shower floor...
-
Industry Standards
621-94 (1999)e1 Standard Practice for the Use of Metric (SI) Units in Building Design and Construction ASTM E 1155-96 (2001) Standard Test Method for Determining FF Floor...
-
3. Lift Compatibility Exception
One commenter, a manufacturer, agreed that equipment designed for use with an overhead lift should be excepted, and also stated that portable floor lifts should be designed to be compatible...
-
1134A.6 Showers
The maximum slope of the shower floor shall be ½ inch (12.7 mm) per foot in any direction and shall slope to a drain....
-
810 Transportation Facilities
This revision does not substantively change the requirements for the coordination of platforms and vehicle floors. Comment....
- Trench Drain SSB 5038TR .75 Base
- Stanley QCI 200 Series Grade 2 Standard-Duty Interconnected Locks
-
Notes
II The IDeA Center in its research defined wheelchair wheelbase as the distance from the center of the primary drive wheel to the center of the caster measured parallel to the floor....
-
IV. Program Access
., moving a public information office from the third floor to the first floor of a building....
-
11B-604.7 Dispensers and disposal units
The outlet of the dispenser shall be below the grab bar, 19 inches (483 mm) minimum above the finish floor and shall not be located behind grab bars....
-
11B-407.2.1.1 Height
[2010 ADAS] EXCEPTION: Existing call buttons and existing keypads shall be permitted to be located at 54 inches (1370 mm) maximum above the finish floor, measured to the centerline...
-
M301.4 Lift Compatibility
, diagnostic equipment shall not be required to meet the lift compatibility requirements of this section provided that such equipment is clearly labeled as not compatible with portable floor...
-
M302.4 Lift Compatibility
, diagnostic equipment shall not be required to meet the lift compatibility requirements of this section provided that such equipment is clearly labeled as not compatible with portable floor...
-
Basic Features
Careful planning and design will incorporate elements such as a wider entrance door, adequate clear floor space, appropriate placement and models of fixtures and furniture, and grab bars...
-
802.1.4 Approach
Because accessible routes serving wheelchair spaces are not permitted to overlap the clear floor space at wheelchair spaces, access to any wheelchair space cannot be through another wheelchair...
-
5.8.2 Knee and Toe Clearance Under Breast Platform
deep, from the initially proposed 25 inch absolute dimension; increasing the knee clearance directly underneath the breast platform to a minimum of 18 inches; and assuring unobstructed floor...
-
4.21.3 SEAT
The seat shall be mounted 17 in to 19 in (430 mm to 485 mm) from the bathroom floor and shall extend the full depth of the stall. The seat shall be on the wall opposite the controls....
-
What types of electrical or communication receptacles are exempt because they serve a “dedicated use”?
Floor electrical receptacles are also exempt. Communication receptacles serving a dedicated use include phone jacks, data ports, network and audio-visual connections....
-
11B-407.2.1.1 Height
[2010 ADAS] EXCEPTION: Existing call buttons and existing keypads shall be permitted to be located at 54 inches (1370 mm) maximum above the finish floor, measured to the centerline of...
-
11B-604.7.2 Disposal units
The disposal unit shall be located below the grab bar with the opening of the disposal unit 19 inches minimum (483 mm) above the finish floor....
-
11B-407.2.1.1 Height
[2010 ADA Standards] EXCEPTION: Existing call buttons and existing keypads shall be permitted to be located at 54 inches (1370 mm) maximum above the finish floor, measured to the centerline...