In buildings where a required accessible floor is four or more stories above or below a level of exit discharge, at least one required accessible means of egress shall be an elevator complying...
Search Results "Floor Surface"
-
1003.2.13.1.1 Buildings with four or more stories
-
407.2.2.2 Visible Signals
Visible signal fixtures shall be centered at 72 inches (1830 mm) minimum above the finish floor or ground....
-
217.2 Wheelchair Accessible Telephones
Table 217.2 Wheelchair Accessible Telephones Number of Telephones Provided on a Floor, Level, or Exterior Site Minimum Number of Required Wheelchair Accessible...
-
1009.2.1 Elevators required
In buildings where a required accessible floor is four or more stories above or below a level of exit discharge, at least one required accessible means of egress shall be an elevator complying...
-
1009.2.1 Elevators required
In buildings where a required accessible floor is four or more stories above or below a level of exit discharge, not less than one required accessible means of egress shall be an elevator...
-
11B-1002.4.3 Gaps
Floors of amusement rides with wheelchair spaces and floors of load and unload areas shall be coordinated so that, when amusement rides are at rest in the load and unload position, the vertical...
-
1002.4.3 Gaps
Floors of amusement rides with wheelchair spaces and floors of load and unload areas shall be coordinated so that, when amusement rides are at rest in the load and unload position, the vertical...
-
1002.4.3 Gaps
Floors of amusement rides with wheelchair spaces and floors of load and unload areas shall be coordinated so that, when amusement rides are at rest in the load and unload position, the...
-
§ 38.23(c)(5) Slope
If the height of the vehicle floor from which the ramp is deployed is 3 inches or less above a 6-inch curb, a maximum slope of 1:4 is permitted; if the height of the vehicle floor from which...
-
11B-1002.4.3 Gaps
Floors of amusement rides with wheelchair spaces and floors of load and unload areas shall be coordinated so that, when amusement rides are at rest in the load and unload position, the vertical...
-
11B-1002.4.3 Gaps
Floors of amusement rides with wheelchair spaces and floors of load and unload areas shall be coordinated so that, when amusement rides are at rest in the load and unload position, the vertical...
-
COMPARISON OF OBJECTIVE MEASURES AND ENERGY COSTS
COMPARISON OF OBJECTIVE MEASURES AND ENERGY COSTS Objective measures of surface firmness and stability were compared to energy costs (energy consumption, velocity, RPE and level of difficulty...
-
11B-809.9.2 Clear width
Kitchens shall have a minimum clear width measured between any cabinet, work surface or the face of any appliance (excluding handles and controls) and the opposing cabinet, work surface,...
-
11B-809.1.2 Viewing devices
entry door to a residential dwelling units with mobility features shall also provide a lower viewing device 42 inches (1067 mm) minimum and 43 inches (1092 mm) maximum above the finish floor...
-
11B-403.5.1 Clear width
Except as provided in Sections 11B-403.5.2 and 11B-403.5.3, the clear width of walking surfaces shall be 36 inches (914 mm) minimum....
-
11B-403.5.1 Clear width
Except as provided in Sections 11B-403.5.2 and 11B-403.5.3, the clear width of walking surfaces shall be 36 inches (914 mm) minimum....
-
M7
If the door swings into the room, does the door swing not overlap the required clear floor space for the toilet or lavatory?...
-
§ 36.404(b)
For example, alterations to floors above or below the accessible ground floor must be accessible regardless of whether the altered facility has an elevator....
-
Sec.36.404(b)
For example, alterations to floors above or below the accessible ground floor must be accessible regardless of whether the altered facility has an elevator....
-
7.3(2)
(2) Clear aisle width for accessible check-out aisles shall comply with 4.2.1 and maximum adjoining counter height shall not exceed 38 in (965 mm) above the finish floor....
-
Curbs [4.21.7]
Curbs [4.21.7] Curbs are limited to ½ inch (measured from the room floor and the shower floor) so as not to interfere with entry to the shower....
-
Flush Controls [4.16.5]
Flush Controls [4.16.5] Flush valve controls must be mounted no more than 44 inches above the floor on the wide side of the toilet so that they are within reach from the available clear...
-
Door and Gate Hardware: ADA Standard Section 404.2.7
Section 404.2.7 covers the current ADA Standards for door and gate hardware.
-
Size: ADA Standard Section 604.8.1.1
Section 604.8.1.1 covers the current ADA Standards for the size of wheelchair accessible compartments.