It helps us to reach out to individuals and organizations that can provide greater evidence for the necessity of the rule....
Search Results "Maximum Reach Depth"
-
Rulemaking Process
-
NOTES
[and] to a position low enough [19 inches maximum] to allow for the comfort of providers who choose to work in a seated position, to enable patients to keep their feet on the floor while...
- AJW Architectural Products U6104EA Unidoor Automatic Roll Towel Dispenser & Waste Receptacle Combination - Recessed
- Pilot Rock APTX Snow Load/Extreme Load Full Size Pedestal Utility Table
- TOTO® Commercial Washout High Efficiency Urinal, 0.5 GPF - ADA
- Open Sesame Remote Controlled Low-Voltage Door System
- Door King Inc. 1802 and 1802-EPD Electronic Programmable Directory Telephone Entry System
- Excel Dryer, Inc. CAST Cover Series HANDS ON® Push Button Activated Hand Dryers and Hair Dryers
- Ytterberg Scientific Inc. FloorPro® Floor Flatness Measurement Device
-
Section 36.211 Maintenance of Accessible Features (Preamble, Section-by-Section Analysis)
The Act requires that, to the maximum extent feasible, facilities must be accessible to, and usable by, individuals with disabilities....
-
Dispersion
In the final rule, the Board has revised the dispersion requirement to allow some overlap (10% maximum) between rooms and to ensure that at least one room provides both wheelchair access...
-
36 CFR Part 1195 Standards for Accessible Medical Diagnostic Equipment - Preamble
The MDE Standards will allow independent entry to, use of, and exit from the equipment by individuals with disabilities to the maximum extent possible....
-
5.8.1.2.1 Ramped Entry Slope Recommendations
The maximum slope for a ramp in the 2010 Standards is a rise of 1 vertical inch for each 12 inches of horizontal distance slope....
-
ADOPTION OF A 19 INCH HEIGHT MINIMIZES COSTS TO HEALTH CARE PROVIDERS
OF A 19 INCH HEIGHT MINIMIZES COSTS TO HEALTH CARE PROVIDERS In the absence of Committee consensus commending a departure from the existing broadly accepted transfer surface height maximum...
-
Introduction
104.1.1 and clarified in its advisory, they are intended to apply only to certain sections of the 2010 ADA Standards where dimensions are stated as single dimensions or as simple minimums or maximums...
-
§35.133 Maintenance of Accessible Features
The Act requires that, to the maximum extent feasible, facilities must be accessible to, and usable by, individuals with disabilities....
-
Protocol A Heights Obtained
The upper 95th percentile transfer heights were 3" higher for the NDVWSC than the HERL group for the maximum height transfer....
-
1. Sloped Surfaces
The maximum running slope generally allowed for ramps is 1:12 (8.33% or 4.76 degrees). Cross slope is the slope or grade of a surface perpendicular to the running slope....
-
§35.133 Maintenance of accessible features (Section-by-Section Analysis)
The Act requires that, to the maximum extent feasible, facilities must be accessible to, and usable by, individuals with disabilities....
-
1017.4 Passing Spaces
This section requires passing spaces to be provided at intervals of 1000 feet maximum where the clear tread width of trails is less than 60 inches....
-
Section 36.211 Maintenance of Accessible Features (Section-By-Section Analysis and Response to Comments)
The Act requires that, to the maximum extent feasible, facilities must be accessible to, and usable by, individuals with disabilities....
-
Circulation Paths
Free-standing objects mounted on posts or pylons may overhang 12 in (305 mm) maximum from 27 in to 80 in (685 mm to 2030 mm) above the ground or finished floor (see Fig. 8(c) and (d))....
-
11B-406.5.3 Landings
The slope of the landing in all directions shall be 1:48 maximum. [2010 ADA Standards] 406.4 Landings. Landings shall be provided at the tops of curb ramps....
-
232.2.1 Cells with Mobility Features
cells other than those where alterations are originally planned), provided that each substitute cell: (i) is located within the same prison site; (ii) Is integrated with other cells to the maximum...