Exceptions: Accessible routes serving floating fishing piers and platforms shall be permitted to use Exceptions 1, 2, 5, 6, 7 and 8 in Section 11B-1003.2.1....
Search Results "Grade 2 Braille"
-
11B-1005.1 Accessible routes
-
11B-608.7 Thresholds
Exception: A threshold 2 inches (51 mm) high maximum shall be permitted in transfer type shower compartments in existing facilities where provision of a ½ inch (12.7 mm) high threshold would...
-
1.1.8.2 Locally adopted energy standards - California Energy Code, Part 6.
Applicable provisions of Public Resources Code Section 25402.1(h)(2) and applicable provisions of Section 10-106, Chapter 10 of California Administrative Code, Part 1 apply to locally adopted...
-
11B-703.7.2.7 Pedestrian traffic-control buttons
Pole-supported pedestrian traffic-control buttons shall be identified with color coding consisting of a textured horizontal yellow band 2 inches (51 mm) in width encircling the pole, and...
-
1133A.7 Knee and toe space
Knee and toe space, when required by Section 1133A, shall comply with Section 1138A.2 and the following: The knee and toe space shall be clear and unobstructed, or removable base cabinets...
-
229.1 General
Glazed openings in residential dwelling units required to comply with 809 shall not be required to comply with 229. 2....
-
229.1 General
Glazed openings in residential dwelling units required to comply with 809 shall not be required to comply with 229. 2....
-
608.7 Thresholds
EXCEPTION: A threshold 2 inches (51 mm) high maximum shall be permitted in transfer type shower compartments in existing facilities where provision of a ½ inch (13 mm) high threshold would...
-
801.1 Scope
The provisions of Chapter 8 shall apply where required by Chapter 2 or where referenced by a requirement in this code. Advisory 801.1 Scope....
-
407.4.6.1 Location
panel serves more than 16 openings and a parallel approach is provided, buttons with floor designations shall be permitted to be 54 inches (1370 mm) maximum above the finish floor. 2....
-
1009.2.1 Pool Lift Location
Where the entire pool depth is greater than 48 inches (1220 mm), compliance with 1009.2.1 shall not be required. 2....
- Allegion LCN 2030 Series Overhead Concealed Door Control
- Allegion LCN 2010 Series Overhead Concealed Door Control
- BEA Inc. PBJ Series Jamb Style Push Plates (Push to Open)
- Midmark Ritter 223 Barrier-Free® Power Examination Table
- Landscape Forms Inc. Petoskey Trash Receptacle
- Spectrum Aquatics Traveler II XRC500 Pool Lift
- Spectrum Aquatics Portable Aspen Pool Lift
-
Section D: Entrances
D8 Are door thresholds no higher than 1/2"?...
-
Diagonal Curb Ramps
Requirements for diagonal curb ramps in section 406.6 also specify that a segment of straight curb at least 2 feet long must be provided on each side of the curb ramp and within the marked...
-
404.2.4.1 Swinging Doors and Gates
inches (1525 mm) 36 inches (915 mm) From hinge side Pull 54 inches (1370 mm) 42 inches (1065 mm) From hinge side Push 42 inches (1065 mm)2...
-
§ 382.53 Medical certificates
(2) For purposes of this paragraph, a medical certificate is a written statement from the passenger’s physician saying that the passenger is capable of completing a flight safely, without...
-
§ 382.47 Accommodations for persons with hearing impairments
(1) Except as provided in paragraph (b)(2) of this section, the carrier shall implement this requirement by using open captioning or an inset for a sign language interpreter as part...
-
11B-106.5 Defined terms
The following terms are defined in Chapter 2, Section 202. Advisory 11B-106.5 Defined terms. ...