maximum shall be permitted in transfer type shower compartments in existing facilities where provision of a ½ inch (13 mm) high threshold would disturb the structural reinforcement of the floor...
Search Results "Floor Plan"
Commonly Searched Documents
-
11B-608.7 Thresholds
-
11B-217.4 TTYs
Separate requirements are provided based on the number of public pay telephones provided at a bank of telephones, within a floor, a building, or on a site....
-
608.5.2 Standard Roll-In Type Shower Compartments
In standard roll-in type shower compartments, the controls, faucets, and shower spray unit shall be located above the grab bar, but no higher than 48 inches (1220 mm) above the shower floor...
-
I don’t want to discriminate against patients with disabilities, but I don’t want my staff to injure their backs by lifting people who use wheelchairs onto exam tables. If my nurse has a bad back, then she doesn’t have to help lift a patient, does she?
The medical provider can protect his or her staff from injury by providing accessible equipment, such as an adjustable exam table and/or a ceiling or floor based patient lift, and training...
-
3. What types of complaints does the ADA Mediation Program resolve?
refuses to serve a person with a disability because he or she uses a service animal; and, Program accessibility: alleging that a city hall's public meetings are held on the second floor...
-
606 Lavatories and Sinks
These specifications concern clear floor space requirements (606.2, Exception 3) and heights (606.3, Exception 2)....
-
M302.2.1 Adjustability (Section-by-Section Analysis)
position of 25 inches; (3) at least four additional transfer positions located between the low and high transfer positions and separated by one inch minimum increments; (4) measured from the floor...
-
608.5.3 Alternate Roll-In Type Shower Compartments
In alternate roll-in type shower compartments, the controls, faucets, and shower spray unit shall be located above the grab bar, but no higher than 48 inches (1220 mm) above the shower floor...
-
608.5.2 Standard Roll-In Type Shower Compartments
In standard roll-in type shower compartments, the controls, faucets, and shower spray unit shall be located above the grab bar, but no higher than 48 inches (1220 mm) above the shower floor...
-
608.3 Grab Bars
Where multiple grab bars are used, required horizontal grab bars shall be installed at the same height above the finish floor. EXCEPTIONS: 1....
-
Measuring Surface Firmness and Stability
The rotational penetrometer (RP) is a precision surface-indenter measuring tool for evaluating the firmness and stability of ground and floor surfaces (figure 1). ...
-
Path of Travel
§36.403(e)(2) An accessible path of travel may consist of walks and sidewalks, curb ramps and other interior or exterior pedestrian ramps; clear floor paths through lobbies, corridors...
-
608.3 Grab Bars
Where multiple grab bars are used, required horizontal grab bars shall be installed at the same height above the finish floor. EXCEPTIONS: 1....
-
11B-411.2.2.2 Verbal identification
volume shall be at least 10 dB above ambient sound level, but shall not exceed 80 dB, measured 36 inches (914 mm) in front of the elevator entrance and at 48 inches (1219 mm) above the floor...
-
608.5.3 Alternate Roll-In Type Shower Compartments
In alternate roll-in type shower compartments, the controls, faucets, and shower spray unit shall be located above the grab bar, but no higher than 48 inches (1220 mm) above the shower floor...
-
Access to Performing Areas [4.33.5]
Access to Performing Areas [4.33.5] An accessible route must connect wheelchair spaces with performing areas, including stages, arena floors, playing fields, dressing and locker rooms...
-
Tactile Signage
Examples include signs labeling restrooms, exits, rooms/floors by number or letter. Recommendation: Tactile signs are recommended for room names not likely to change....
-
4.17.3* Size and Arrangement
If the depth of a standard toilet stall is increased at least 3 in (75 mm), then a floor-mounted water closet may be used....
-
Locating Controls & Devices: Percent of People Who Can Reach the Matrix Cell Indicated While Holding 5 lb Weight - Forward Approach Power Chair
abilities of power chair users represented as the percentage of users able to retrieve and place a 5 lb weight on a target shelf in the forward reach direction for a given (a) height from the floor...
-
Locating Controls & Devices: Percent of People Who Can Reach the Matrix Cell Indicated While Holding 5 lb Weight - Forward Approach Manual Wheelchair
abilities of manual chair users represented as the percentage of users able to retrieve and place a 5 lb weight on a target shelf in the forward reach direction for a given (a) height from the floor...
-
4.10.4 HALL LANTERNS
Visible signals shall have the following features: (1) Hall lantern fixtures shall be mounted so that their centerline is at least 72 in (1830 mm) above the lobby floor....
-
4.6.3* PARKING SPACES
accessible parking spaces for vans designed for handicapped persons are provided, each should have an adjacent access aisle at least 96 in (2440 mm) wide complying with 4.5, Ground and Floor...
-
11B-411.2.2.2 Verbal identification
volume shall be at least 10 dB above ambient sound level, but shall not exceed 80 dB, measured 36 inches (914 mm) in front of the elevator entrance and at 48 inches (1219 mm) above the floor...