Kitchens, kitchenettes and wet bars shall comply with Section 11B-804. [2010 ADA Standards] 806.2.5 Kitchens and Kitchenettes. Kitchens and kitchenettes shall comply with 804....
Search Results "Shall"
Commonly Searched Documents
-
11B-806.2.5 Kitchens, kitchenettes and wet bars
-
11B-1009.5.1 Transfer platform
A transfer platform shall be provided at the head of each transfer system....
-
11B-303.2 Vertical
Changes in level of ¼ inch (6.4 mm) high maximum shall be permitted to be vertical and without edge treatment. [2010 ADA Standards] 303.2 Vertical....
-
11B-812.8.2 Five to twenty-five
Where five to twenty-five total EVCS are provided, one van accessible EVCS shall be identified by an ISA complying with Section 11B-703.7.2.1....
-
11B-308.2.1 Unobstructed
Where a forward reach is unobstructed, the high forward reach shall be 48 inches (1219 mm) maximum and the low forward reach shall be 15 inches (381 mm) minimum above the finish floor or...
-
11B-809.10.8 Lavatories, vanities, mirrors and towel bars
Bathing rooms or powder rooms required to comply with Section 11B-809.10 shall provide lavatories complying with this section....
-
11B-406.3.2 Turning space
A turning space 48 inches (1219 mm) minimum by 48 inches (1219 mm) minimum shall be provided at the bottom of the curb ramp....
-
11B-405.1 General
Ramps on accessible routes shall comply with Section 11B-405....
-
11B-703.5.8 Character spacing
Character spacing shall be measured between the two closest points of adjacent characters, excluding word spaces....
-
II. COMPLIANCE WITH TITLE III OF THE ADA
Web Accessibility Coordinator: By June 15, 2014, H&R Block shall designate an employee, who shall report directly to H&R Block’s enterprise Chief Information Officer as the Web Accessibility...
-
207.1 General
Means of egress shall comply with section 1003.2.13 of the International Building Code (2000 edition and 2001 Supplement) or section 1007 of the International Building Code (2003 edition...
-
F207.1 General
Means of egress shall comply with section 1003.2.13 of the International Building Code (2000 edition and 2001 Supplement) or section 1007 of the International Building Code (2003 edition...
-
1009.3.2 Submerged Depth
Sloped entries shall extend to a depth of 24 inches (610 mm) minimum and 30 inches (760 mm) maximum below the stationary water level....
-
11B-1005.1 Accessible routes
Accessible routes serving fishing piers and platforms, including gangways and floating piers, shall comply with Division 4. Exceptions: 1. ...
-
216.11 Check-Out Aisles
Where more than one check-out aisle is provided, check-out aisles complying with 904.3 shall be identified by the International Symbol of Accessibility complying with 703.7.2.1....
-
F211.3 More Than Minimum Number
Where more than the minimum number of drinking fountains specified in F211.2 are provided, 50 percent of the total number of drinking fountains provided shall comply with 602.1 through 602.6...
-
1008.4.3 Play Tables
Where play tables are provided, knee clearance 24 inches (610 mm) high minimum, 17 inches deep (430 mm) minimum, and 30 inches (760 mm) wide minimum shall be provided....
-
1007.11 Instructions
In areas of refuge and exterior areas for assisted rescue, instructions on the use of the area under emergency conditions shall be posted....
-
F202.6 Leases
effective date of the revised standards issued pursuant to the Architectural Barriers Act, including new leases for buildings or facilities previously occupied by the Federal government, shall...
-
607.4.2.1 Back Wall
Two grab bars shall be installed on the back wall, one located in accordance with 609.4 and other located 8 inches (205 mm) minimum and 10 inches (255 mm) maximum above the rim of the bathtub...
-
1008.4.3 Play Tables
Where play tables are provided, knee clearance 24 inches (610 mm) high minimum, 17 inches deep (430 mm) minimum, and 30 inches (760 mm) wide minimum shall be provided....
-
306.1 General
Where space beneath an element is included as part of clear floor or ground space or turning space, the space shall comply with 306....
-
602.2 Clear Floor Space
Units shall have a clear floor or ground space complying with 305 positioned for a forward approach and centered on the unit....
-
608.7 Thresholds
Thresholds in roll-in type shower compartments shall be 1/2 inch (13 mm) high maximum in accordance with 303....