A transfer space complying with Sections 11B-305.2 and 11B-305.3 shall be provided adjacent to the transfer platform....
Search Results "Shall"
-
11B-1008.3.1.3 Transfer space
-
M304.2.2 Standing Supports
Standing supports shall be provided on two sides of the standing surface and shall comply with M305.3....
-
11B-223.2 Hospitals, rehabilitation facilities, psychiatric facilities and detoxification facilities
Hospitals, rehabilitation facilities, psychiatric facilities and detoxification facilities shall comply with Section 11B-223.2....
-
1009.5.2 Transfer Space
A transfer space of 60 inches (1525 mm) minimum by 60 inches (1525 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer platform surface and shall...
-
505.10.1 Top and Bottom Extension at Ramps
Ramp handrails shall extend horizontally above the landing for 12 inches (305 mm) minimum beyond the top and bottom of ramp runs....
-
F204.1 General
Protruding objects on circulation paths shall comply with 307. EXCEPTIONS: 1....
-
404.3 Automatic and Power-Assisted Doors and Gates
Automatic doors and automatic gates shall comply with 404.3....
-
407.2.1.5 Signals
Call buttons shall have visible signals to indicate when each call is registered and when each call is answered. EXCEPTIONS: 1....
-
404.3 Automatic and Power-Assisted Doors and Gates
Automatic doors and automatic gates shall comply with 404.3....
-
204.1 General
Protruding objects on circulation paths shall comply with 307. EXCEPTIONS: 1....
-
402.4 Characters on Display Screens
At least one mode of characters displayed on the screen shall be in a sans serif font....
-
407.3.3 Numeric Keys
Where provided, numeric keys shall be arranged in a 12-key ascending or descending keypad layout. The number five key shall be tactilely distinct from the other keys....
-
711.2 Installation details
Where sleeves are used, they shall be securely fastened to the assembly penetrated....
-
505.10.1 Top and Bottom Extension at Ramps
Ramp handrails shall extend horizontally above the landing for 12 inches (305 mm) minimum beyond the top and bottom of ramp runs....
-
505.10.2 Top Extension at Stairs
At the top of a stair flight, handrails shall extend horizontally above the landing for 12 inches (305 mm) minimum beginning directly above the first riser nosing....
-
1008.1.9.7, Item 5
A sign shall be provided on the door located above and within 12 inches (305 mm) of the release device reading: “KEEP PUSHING....
-
5.3.3.2 Location Where Walls Provided
Where walls or partitions are provided, the seat shall be positioned with a wall or partition to the rear and to one side of the seat for a left-hand or right-hand approach. ...
-
4.14.1 Minimum Number
Entrances required to be accessible by 4.1 shall be part of an accessible route complying with 4.3....
-
402.4 Characters
At least one mode of characters displayed on the screen shall be in a sans serif font....
-
4.2.6* Side Reach
If the clear floor space allows parallel approach by a person in a wheelchair, the maximum high side reach allowed shall be 54 in (1370 mm) and the low side reach shall be no less than 9...
-
4.21.2 Size and Clearances
Except as specified in 9.1.2, shower stall size and clear floor space shall comply with Fig. 35(a) or (b). The shower stall in Fig. 35(a) shall be 36 in by 36 in (915 mm by 915 mm)....
-
4.18.3 Clear Floor Space
A clear floor space 30 in by 48 in (760 mm by 1220 mm) shall be provided in front of urinals to allow forward approach....
-
5.3.3.2 Location Where Walls Provided
Where walls or partitions are provided, the seat shall be positioned with a wall or partition to the rear and to one side of the seat for a left-hand or right-hand approach....
-
4.18.3 CLEAR FLOOR SPACE
A clear floor space 30 in by 48 in (760 mm by 1220 mm) shall be provided in front of urinals to allow forward approach....