Elevator car controls shall comply with 407.4.6. Control panels shall be centered on a side wall....
Search Results "Shall"
-
408.4.6 Car Controls
-
408.3.2 Swinging Doors
Swinging hoistway doors shall open and close automatically and shall comply with 404, 407.3.2 and 408.3.2....
-
903.7 Wet Locations
Where installed in wet locations, the surface of the seat shall be slip resistant and shall not accumulate water....
-
409.4.6 Car Controls
Elevator car control buttons shall comply with 409.4.6, 309.3, 309.4, and shall be raised or flush....
-
F212.3 Sinks
Where sinks are provided, at least 5 percent, but no fewer than one, of each type provided in each accessible room or space shall comply with 606. EXCEPTIONS: 1....
-
11B-703.7.2.6.2 Women’s toilet and bathing facilities
Women’s toilet and bathing facilities shall be identified by a circle, ¼ inch (6.4 mm) thick and 12 inches (305 mm) in diameter....
-
608.3.3 Alternate Roll-In Type Shower Compartments
In alternate roll-in type shower compartments, grab bars shall be provided on the back wall and the side wall farthest from the compartment entry....
-
407.2.1.5 Signals
Call buttons shall have visible signals to indicate when each call is registered and when each call is answered. EXCEPTIONS: 1....
-
11B-805.2.2 Beds
A 36 inch (914 mm) minimum wide clear space shall be provided along the full length of each side of the beds. [2010 ADAS] 805.3 Clear Floor or Ground Space. ...
-
11B-1008.3.1.3 Transfer space
A transfer space complying with Sections 11B-305.2 and 11B-305.3 shall be provided adjacent to the transfer platform....
-
M304.2.2 Standing Supports
Standing supports shall be provided on two sides of the standing surface and shall comply with M305.3....
-
11B-223.2 Hospitals, rehabilitation facilities, psychiatric facilities and detoxification facilities
Hospitals, rehabilitation facilities, psychiatric facilities and detoxification facilities shall comply with Section 11B-223.2....
-
505.10.1 Top and Bottom Extension at Ramps
Ramp handrails shall extend horizontally above the landing for 12 inches (305 mm) minimum beyond the top and bottom of ramp runs....
-
F204.1 General
Protruding objects on circulation paths shall comply with 307. EXCEPTIONS: 1....
-
404.3 Automatic and Power-Assisted Doors and Gates
Automatic doors and automatic gates shall comply with 404.3....
-
402.4 Characters on Display Screens
At least one mode of characters displayed on the screen shall be in a sans serif font....
-
407.3.3 Numeric Keys
Where provided, numeric keys shall be arranged in a 12-key ascending or descending keypad layout. The number five key shall be tactilely distinct from the other keys....
-
711.2 Installation details
Where sleeves are used, they shall be securely fastened to the assembly penetrated....
-
1008.1.9.7, Item 5
A sign shall be provided on the door located above and within 12 inches (305 mm) of the release device reading: “KEEP PUSHING....
-
5.3.3.2 Location Where Walls Provided
Where walls or partitions are provided, the seat shall be positioned with a wall or partition to the rear and to one side of the seat for a left-hand or right-hand approach. ...
-
4.14.1 Minimum Number
Entrances required to be accessible by 4.1 shall be part of an accessible route complying with 4.3....
-
402.4 Characters
At least one mode of characters displayed on the screen shall be in a sans serif font....
-
4.2.6* Side Reach
If the clear floor space allows parallel approach by a person in a wheelchair, the maximum high side reach allowed shall be 54 in (1370 mm) and the low side reach shall be no less than 9...
-
4.21.2 Size and Clearances
Except as specified in 9.1.2, shower stall size and clear floor space shall comply with Fig. 35(a) or (b). The shower stall in Fig. 35(a) shall be 36 in by 36 in (915 mm by 915 mm)....