- AquaTrek2 ADA Wading Pool Ramp
- Allegion Schlage LT Series Mechanical Locks with Tubular Interconnect
- PEMKO 5 9/16" Thermal Barrier Threshold No. 273x292-FGPK
-
Ask Questions and Provide Instructions
If you are receiving assistance with transportation between gates by ground wheelchair, remember to instruct the personnel assisting you on your specific needs, e.g., whether or not you...
-
Summary: What Every Playground Owner Should Know About the Accessibility of Their Playground Surfaces
Playground owners, designers and maintenance personnel must have a good understanding of the requirements for ground level accessible routes within the play area. ...
-
11B-211.1 General
Where drinking fountains are provided on an exterior site, on a floor, or within a secured area they shall be provided in accordance with Section 11B-211....
-
407.2.1.1 Height
EXCEPTION: Existing call buttons and existing keypads shall be permitted to be located at 54 inches (1370 mm) maximum above the finish floor, measured to the centerline of the highest operable...
-
604.9.5 Flush Controls
Hand operated flush controls shall comply with 309.2 and 309.4 and shall be installed 36 inches (915 mm) maximum above the finish floor....
-
604.9.5 Flush Controls
Hand operated flush controls shall comply with 309.2 and 309.4 and shall be installed 36 inches (915 mm) maximum above the finish floor....
-
407.2.1.1 Height
EXCEPTION: Existing call buttons and existing keypads shall be permitted to be located at 54 inches (1370 mm) maximum above the finish floor, measured to the centerline of the highest operable...
-
M302.2.1 Height
The height of the transfer surface during patient transfer shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum measured from the floor to the top of the transfer surface....
-
M301.2.1 Height
The height of the transfer surface during patient transfer shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum measured from the floor to the top of the transfer surface....
-
11B-211.1 General
Where drinking fountains are provided on an exterior site, on a floor, or within a secured area they shall be provided in accordance with Section 11B-211. ...
-
11B-211.1 General
Where drinking fountains are provided on an exterior site, on a floor, or within a secured area they shall be provided in accordance with Section 11B-211....
-
Hand Cycles (Stand-Alone)
The caster wheels do not touch the ground unless the rider leans the bicycle to one side or the other....
-
§ 38.83(b)(2)(i) Requirements
., ground, curb, and intermediate positions) normally encountered in the operating environment....
-
§ 38.23(b)(2)(i) Requirements
., ground, curb, and intermediate positions) normally encountered in the operating environment....
-
§ 38.159(b)(2)(i) Requirements
., ground, curb, and intermediate positions) normally encountered in the operating environment....
- Cybex Total Access Row/Rear Delt Exercise Machine
-
11B-802.1.4 Approach
Because accessible routes serving wheelchair spaces are not permitted to overlap the clear floor space at wheelchair spaces, access to any wheelchair space cannot be through another wheelchair...
-
T404.3 Ramps and Bridgeplates
Where the space between the floor of non-rail vehicles and a boarding platform is greater than 2 inches (51 mm) horizontally or 5/8 inch (16 mm) vertically when measured at 50 percent passenger...
-
4. Grab Bars
Does the toilet in each accessible guestroom bathroom have a horizontal grab bar along the adjacent side wall that is at least 42" long and mounted 33"-36" above the floor for stabilization...
-
G. Compartment Size