The Department has adopted the Option One guidelines for Requirement 4 with the following changes: First, the Department has eliminated the specification for maneuvering space if a person...
Search Results "Lavatory Clear Floor Space"
-
Guidelines for Requirement 4
-
M303.3.1 Vertical
Changes in level of ¼ inch (6.4 mm) high maximum shall be permitted to be vertical.
-
A4.8.2 SLOPE AND RISE
The ability to manage an incline is related to both its slope and its length. Wheelchair users with disabilities affecting arms or with low stamina have serious difficulty using...
-
M303.1 General
Diagnostic equipment used by patients seated in a wheelchair shall comply with M303.
-
A4.8.2 Slope and Rise
Ramp slopes between 1:16 and 1:20 are preferred. The ability to manage an incline is related to both its slope and its length. Wheelchair users with disabilities affecting their arms...
-
M303.3.2 Beveled
Changes in level between ¼ inch (6.4 mm) high and ½ inch (13 mm) high maximum shall be beveled with a slope not steeper than 1:2.
-
11B-806.2.4.1 Vanity counter top space
If vanity counter top space is provided in non-accessible guest toilet or bathing rooms, comparable vanity counter top space, in terms of size and proximity to the lavatory, shall also be...
-
M303.3.2 Beveled
Changes in level between ¼ inch (6.4 mm) high and ½ inch (13 mm) high maximum shall be beveled with a slope not steeper than 1:2.
-
M303.4 Components (Section-by-Section Analysis)
The MDE NPRM proposed to require diagnostic equipment used by patients seated in a wheelchair which has components that are used to examine specific body parts, be capable of...
-
T605 Seat Belts and Shoulder Belts
-
M303.3.1 Vertical
Changes in level of ¼ inch (6.4 mm) high maximum shall be permitted to be vertical.
-
A. ACCESSIBLE SEATING
space requirements set forth in table 221.2.1.1 of the Standards....
-
Floor Designations
The proposed rule specified that tactile floor designations at the hoistway be 60 inches above the floor, measured from the baseline of the characters (407.2.4)....
-
405.5 Clear Width
The clear width of a ramp run and, where handrails are provided, the clear width between handrails shall be 36 inches (915 mm) minimum....
-
3. Exception to Ramp Running Slope
The MDE Advisory Committee, during its discussion of wheelchair spaces on weight scales, extensively addressed the permissible slopes of ramps on raised platforms....
-
1002.4.7.1 Shoulder-to-Shoulder Seating
Where an amusement ride provides shoulder-to-shoulder seating, companion seats shall be shoulder-to-shoulder with the adjacent wheelchair space....
-
T208 Passenger Access Routes
-
405.5 Clear Width
405.5 Clear Width. The clear width of a ramp run and, where handrails are provided, the clear width between handrails shall be 36 inches (915 mm) minimum....
-
ADA & Level Boarding Guidance - Platform Height
49 CFR §§37.41-43; 37.9(a), (d); 49 CFR Part 37, App. A (810.5.3) DECEMBER 14, 2011
-
11B-703.8.9 Height above floor
Low resolution VMS characters shall be 40 inches (1016 mm) minimum above the floor of the viewing position, measured to the baseline of the character....
-
Floor [1014.3]
The floor surface within a camp shelter must be firm and stable....
-
11B-609.3 Spacing
The space between the wall and the grab bar shall be 1½ inches (38 mm). The space between the grab bar and projecting objects below and at the ends shall be 1½ inches (38 mm) minimum....
-
11B-405.4 Floor or ground surfaces
Floor or ground surfaces of ramp runs shall comply with Section 11B-302. Changes in level other than the running slope and cross slope are not permitted on ramp runs....
-
(3) Usable bathrooms
The Act requires that an accessible or "usable" bathroom is one which provides sufficient space for an individual in a wheelchair to maneuver about....