All privately funded public accommodations, as defined and commercial facilities, as defined, shall be accessible to persons with disabilities as follows: Exception: Certain types of...
Search Results "General Exception"
Commonly Searched Documents
-
1.9.1.2
-
233.3.1 Minimum Number: New Construction
EXCEPTION: Where facilities contain 15 or fewer residential dwelling units, the requirements of 233.3.1.1 and 233.3.1.2 shall apply to the total number of residential dwelling units that...
-
309.4 Operation
EXCEPTION: Gas pump nozzles shall not be required to provide operable parts that have an activating force of 5 pounds (22.2 N) maximum....
-
§382.133(a)
(a) Except for on-demand air taxi operators, as a U.S. carrier conducting passenger service you must permit any individual with a disability to use in the passenger cabin during air transportation...
-
1007.7.6 Stairway
Exception: The clear width of 48 inches (1219 mm) between handrails is not required at stairways serving buildings equipped throughout with an automatic sprinkler system installed in accordance...
-
M304.2.2 Standing Supports
EXCEPTION: Diagnostic equipment with entry and exit permitting pass-through from one end to the other shall be permitted to provide one standing support on one side of the standing surface...
-
Federal Agency
Any Executive agency or any establishment in the legislative or judicial branch of the Government (except the Senate, the House of Representatives, and the Architect of the Capitol and any...
-
404.3.6 Break Out Opening
EXCEPTION: Where manual swinging doors and gates comply with 404.2 and serve the same means of egress compliance with 404.3.6 shall not be required....
-
11B-407.2.1.6 Keypads
ETA Editor's Note Lacking certain Exceptions allowed by 2010 ADAS, and imposing additional requirements regarding call buttons, the preceding 2013 CBC requirements pertaining to elevator...
-
F246.4 Outdoor Recreation Access Routes
There are exceptions in 1016.1 that can be used where conditions specified in 1019 apply....
-
F211.2 Minimum Number
[ECTCR UFAS 4.1.2(9)] EXCEPTION: Where a single drinking fountain complies with 602.1 through 602.6 and 602.7, it shall be permitted to be substituted for two separate drinking fountains...
-
703.2.5 Character Height
EXCEPTION: Where separate raised and visual characters with the same information are provided, raised character height shall be permitted to be ½ inch (13 mm) minimum....
-
404.3.6 Break Out Opening
EXCEPTION: Where manual swinging doors and gates comply with 404.2 and serve the same means of egress compliance with 404.3.6 shall not be required....
-
407.2.1.5 Signals
EXCEPTIONS: 1....
-
Dumpster Enclosures
common use circulation path to the dumpster enclosure, however, shall not be required to comply with TAS 402 if the employee work area is fully exposed to the weather based on TAS 206.2.8, Exception...
-
E205.4 Accessibility Standard
EXCEPTION: Non-Web documents shall not be required to conform to the following four WCAG 2.0 Success Criteria: 2.4.1 Bypass Blocks, 2.4.5 Multiple Ways, 3.2.3 Consistent Navigation, and...
-
907.2.4 Group F
Exception: Manual fire alarm boxes are not required if the building is equipped throughout with an automatic sprinkler system and the notification appliances will activate upon sprinkler...
-
C.8 - Are Section 508 access requirements satisfied if the agency provides such access following a request for it, as opposed to in anticipation of a request for access?
Section 1194.24 (c) and (d) of the Access Board's standards are to be met at the time the product is developed or, in the case of a procurement, when the product is delivered (unless an exception...
-
902.4 Dining Surfaces and Work Surfaces for Children's Use
EXCEPTION: Dining surfaces and work surfaces that are used primarily by children 5 years and younger shall not be required to comply with 902.4 where a clear floor or ground space complying...
-
11B-604.9.5 Flush controls
Flush controls shall be located on the open side of the water closet except in ambulatory accessible compartments complying with Section 11B-604.8.2....
-
Sec.36.304(d)(1)
1) Except as provided in paragraph (d)(2) of this section, measures taken to comply with the barrier removal requirements of this section shall comply with the applicable requirements for...
-
4.21.2 Size and Clearances
Except as specified in 9.1.2, shower stall size and clear floor space shall comply with Fig. 35(a) or (b). The shower stall in Fig. 35(a) shall be 36 in by 36 in (915 mm by 915 mm)....
-
4.21.6 Shower Unit
EXCEPTION: In unmonitored facilities where vandalism is a consideration, a fixed shower head mounted at 48 in (1220 mm) above the shower floor may be used in lieu of a hand-held shower head...
-
4.21.6 SHOWER UNIT
EXCEPTION: In unmonitored facilities where vandalism is a consideration, a fixed shower head mounted at 48 in (1220 mm) above the shower floor may be used in lieu of a hand-held shower head...