604.6 Flush Controls
-
502.5 Vertical Clearance
Parking spaces for vans and access aisles and vehicular routes serving them shall provide a vertical clearance of 98 inches (2490 mm) minimum. Advisory 502.5 Vertical Clearance....
-
502.5 Vertical Clearance
Parking spaces for vans and access aisles and vehicular routes serving them shall provide a vertical clearance of 98 inches (2490 mm) minimum. Advisory 502.5 Vertical Clearance....
-
City of XXX – ADA Transition Plan
City Hall January 4, 2017 Prepared by: ADA Coordinator and Director of Facilities Area Access Issue Solution Target...
-
Accessible Parking Spaces
When a business restripes a parking lot, it must provide accessible parking spaces as required by the ADA Standards for Accessible Design....
-
What’s the difference between the Air Carrier Access Act (ACAA) and the Americans with Disabilities Act (ADA)?
QUESTION: What’s the difference between the Air Carrier Access Act (ACAA) and the Americans with Disabilities Act (ADA)?...
-
Ticket distribution methods. (Section-by-Section Analysis)
general rule that a public accommodation shall modify its policies, practices, and procedures to ensure that individuals with disabilities can purchase single or multi-event tickets for accessible...
- California Commission on Disability Access (CCDA)
-
11B-703.3.2 Position
Editor's Note 2013 CBC Figure 11B-703.3.2 is not intended to suggest that Braille must be multi-lined when the related text is multi-lined, only to illustrate the required position and spacing...
-
11B-703.3.2 Position
ETA Editor's Note CBC Figure 11B-703.3.2 is not intended to suggest that Braille must be multi-lined when the related text is multi-lined, only to illustrate the required position and spacing...
-
11B-703.3.2 Position
Editor's Note CBC Figure 11B-703.3.2 is not intended to suggest that braille must be multi-lined when the related text is multi-lined, only to illustrate the required position and spacing...
-
M303.2.3.1 Front or Rear Entry
Where wheelchair space entry and exit is provided at only one end (front or rear) the wheelchair space shall be 48 inches (1220 mm) deep minimum....
-
11B-904.4.1 Parallel approach
A clear floor or ground space complying with Section 11B-305 shall be positioned for a parallel approach adjacent to the 36 inch (914 mm) minimum length of counter....
-
11B-904.4.1 Parallel approach
A clear floor or ground space complying with Section 11B-305 shall be positioned for a parallel approach adjacent to the 36 inch (914 mm) minimum length of counter....
-
M303.2.3.2 Pass Through Entry
Where wheelchair space entry and exit permits pass through from one end to the other, the wheelchair space shall be 40 inches deep (1015 mm) minimum....
-
Wheelchair Seating Locations
Platform lifts can be used to provide access to wheelchair locations in order to meet the line of sight or dispersion requirements of 4.33.3....
-
Slopes and Resting Intervals for Outdoor Recreation Access Routes
access route may never exceed 1:10, a 10-percent grade....
-
11B-902.4.1 Clear floor or ground space
A clear floor space complying with Section 11B-305 positioned for forward approach shall be provided....
-
11B-902.4.1 Clear floor or ground space
A clear floor space complying with Section 11B-305 positioned for forward approach shall be provided....
-
Side Reach [4.2.6]
High and low reaches are based on a depth of reach no greater than 10 inches measured from the available clear floor space....
- Power PDF Standard 2 Software
-
Question 10
Is the accessible entrance into the building free of obstacles that block the clear wall and floor space needed for opening the door (between 18 and 42 inches on the latch side of the door...
-
J1
If the drinking fountain is a wall-mounted unit, is there clear floor space at least 30 inches wide (36 inches if it is in an alcove) x 48 inches long in front of the drinking fountain and...
-
11B-904.4.1 Parallel approach
A clear floor or ground space complying with Section 11B-305 shall be positioned for a parallel approach adjacent to the 36 inch (914 mm) minimum length of counter....