Hand operated flush controls shall comply with Section 11B-309 except they shall be located 44 inches (1118 mm) maximum above the floor....
Search Results "Floor Slope"
-
11B-604.6 Flush controls
-
11B-604.6 Flush controls
Hand operated flush controls shall comply with Section 11B-309 except they shall be located 44 inches (1118 mm) maximum above the floor....
-
1009.9 Signage
Signage indicating special accessibility provisions shall be provided as shown: Each door providing access to an area of refuge from an adjacent floor area shall be identified by a...
- Whitehall Mfg. WH3740 Ligature Resistant Stainless Steel Basin
- BraunAbility UVL Wheelchair Lift for Cutaway Buses and Paratransit Vans
-
Accessible Routes (Exterior and Interior)
The route must be free of abrupt changes in level, steps, high thresholds, or steeply sloped walkways....
-
505.6 Gripping Surface
Where handrails are provided along walking surfaces with slopes not steeper than 1:20, the bottoms of handrail gripping surfaces shall be permitted to be obstructed along their entire length...
-
1. Accessible route(s)
On-grade walks or paths between separate buildings with covered multifamily dwellings, while not required, should be accessible unless the slope of finish grade exceeds 8.33% at any point...
-
11B-505.6 Gripping surface
Where handrails are provided along walking surfaces with slopes not steeper than 1:20, the bottoms of handrail gripping surfaces shall be permitted to be obstructed along their entire length...
-
Maintenance (Trail Terminology)
and removing rock slides Maintaining trail tread, such as filling ruts, reshaping a trail bed, repairing a trail surface or washouts, installing riprap to retain cut and fill slopes...
-
11B-406.6 Islands
Each 48 inch (1220 mm) minimum by 36 inch (915 mm) minimum area shall be oriented so that the 48 inch (1220 mm) minimum length is in the direction of the running slope of the curb ramp it...
-
505.6 Gripping Surface
Where handrails are provided along walking surfaces with slopes not steeper than 1:20, the bottoms of handrail gripping surfaces shall be permitted to be obstructed along their entire length...
-
Sales and Service Counters
At counters having a cash register, a section of counter at least 36 inches long and not more than 36 inches above the floor will make the counter accessible....
-
M301.2.1, M302.2.1 Transfer Height
Transfer Height Proposed requirement: The height of the transfer surface during patient transfer shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum measured from the floor...
-
11B-404.2.7 Door and gate hardware
Operable parts of such hardware shall be 34 inches (864 mm) minimum and 44 inches (1118 mm) maximum above the finish floor or ground....
-
11B-404.2.7 Door and gate hardware
Operable parts of such hardware shall be 34 inches (864 mm) minimum and 44 inches (1118 mm) maximum above the finish floor or ground....
-
3. New Construction vs. Alterations
curb ramps installed must meet the accessibility requirements of the ADA to the maximum extent feasible.10 Scoping requirements in the ADA Standards establish limitations for the running slope...
-
T402 Ramps and Bridgeplates
and bridgeplates in the 2016 Non-Rail Vehicle Guidelines include provisions on design load, installation and operation, emergency operation, surfaces, clear width, edge guards, running slope...
-
1132A.4.1 Thresholds
., floor material changes at door thresholds) shall not exceed ½ inch (12.7 mm). Thresholds shall comply with the following:...
-
Accessible Courtroom Stations
Clear floor space for a forward approach is required for all courtroom stations (judges’ benches, clerks’ stations, bailiffs’ stations, deputy clerks’ stations, court reporters’ stations...
-
607 Bathtubs
Specifications for bathtubs in section 607 address clear floor space, seats, grab bars, operable parts, shower spray units, and enclosures....
-
Saunas and Steam Rooms
Doors cannot swing into any part of the clear floor or ground space required for benches....
-
Exercise machines. (Section-by-Section Analysis)
Sections 206.2.13 and 236 of the 2004 ADAAG require one of each type of fixed exercise machine to meet clear floor space specifications and to be on an accessible route. ...
-
Exercise machines. (Section-by-Section Analysis)
Sections 236 and 206.2.13 of the 2004 ADAAG require one of each type of fixed exercise machine to meet clear floor space specifications and to be on an accessible route....