If you place this unit next to the accessible lavatory or other required clear space and don't allow room for the projection, it may interfere with the minimum required clear floor space...
Search Results "Urinal Clear Floor Space"
Commonly Searched Documents
-
This is a great unit but it's not "recessed", it's semi-recessed.
-
Are accessible spaces required on all levels of a multi-level parking structure?
If a parking facility has entrances and exits on one level only, standard and van accessible spaces are required on that level so that they are on the shortest accessible route to the entrance...
-
Accessible Routes
Clear floor space required at play components and maneuvering space can overlap the accessible route. ...
-
2. Commercial Space
[See subsections ...]
-
CHAPTER 8: SPECIAL ROOMS, SPACES, AND ELEMENTS
[See subsections ...]
-
DIVISION 8: SPECIAL ROOMS, SPACES, AND ELEMENTS
[See subsections ...]
-
Clearances: ADA Standard Section 1003.3
Although the minimum width of the clear pier space is 60 inches (1525 mm), it is recommended that piers be wider than 60 inches (1525 mm) to improve the safety for persons with disabilities...
-
Gurney Accessible Bathroom
Movable wall for shower gurney access Vanity remodeled to clear the space for wheelchair users Hand-held shower 6’ hose on shower Shower heads at four...
-
Chapter 9: Built-In Elements
Changes made to this section include: clarification of provisions for benches concerning clear floor or ground space (903.2), back support (903.4), and height (903.5) addition...
-
904.4 Sales and Service Counters
reduction of the number of existing mail boxes, the counter shall be permitted to have a portion which is 24 inches (610 mm) long minimum complying with 904.4.1 provided that the required clear...
-
308.2.2 Obstructed High Reach
Where a high forward reach is over an obstruction, the clear floor space shall extend beneath the element for a distance not less than the required reach depth over the obstruction....
-
904.4 Sales and Service Counters
reduction of the number of existing mail boxes, the counter shall be permitted to have a portion which is 24 inches (610 mm) long minimum complying with 904.4.1 provided that the required clear...
-
9.5 LOCKER ROOMS
., intended for use by people in wheelchairs shall be located no higher than 48 in (1220 mm) above the finished floor....
-
Viewing Areas
Ensure each viewing area that is required to be accessible has a clear ground or floor space that is at least 36 inches (915 millimeters) by 48 inches (1,220 millimeters) and is positioned...
-
Water Closet Location and Rear Grab Bar
Section 604.5.2, Exception 1 permits a shorter grab bar on the rear wall where there is not enough wall space due to special circumstances (e.g., when a lavatory or other recessed fixture...
-
Comparison of Single-User Toilet Room Layouts: Plan 3
A T-shaped turning space has been used (see Fig. 3(a) of the 1991 Standards and Figure 304.3.2 of the 2010 Standards) to maintain a compact room size....
-
Reach Ranges and Operability Requirements
They also need correctly sized spaces to position their wheelchairs to be able to reach objects from the front and from the side....
-
1132A.5.2 Strike edge maneuvering space at doors
1132A.5.2 Strike edge maneuvering space at doors. The width of the level area on the side to which the door swings shall extend 18 inches (457 mm) past the strike edge for all doors....
-
11B-404.2.9 Door and gate opening force
|_, 11B-305 _|Clear Floor or Ground Space|_ and 11B-308 _|Reach Ranges|_....
-
308.3.2 Obstructed High Reach
Where a clear floor or ground space allows a parallel approach to an element and the high side reach is over an obstruction, the height of the obstruction shall be 34 inches (865 mm) maximum...
-
308.3.2 Obstructed High Reach
Where a clear floor or ground space allows a parallel approach to an element and the high side reach is over an obstruction, the height of the obstruction shall be 34 inches (865 mm) maximum...
-
308.3.2 Obstructed High Reach
Where a clear floor or ground space allows a parallel approach to an element and the high side reach is over an obstruction, the height of the obstruction shall be 34 inches (865 mm) maximum...
-
11B-308.3.2 Obstructed high reach
Where a clear floor or ground space allows a parallel approach to an element and the high side reach is over an obstruction, the height of the obstruction shall be 34 inches (864 mm) maximum...