Alterations to such facilities are required to be done in full compliance with the alteration requirements for other types of buildings....
Search Results "Technical Requirement"
-
Historic Preservation [4.1.7]
-
4) Medical or health care facilities
The required percentage is 100 percent for special facilities treating conditions that affect mobility, and 50 percent for long-term care facilities and nursing homes....
-
11B-505.1 General
Handrails provided along walking surfaces complying with Section 11B-403, required at ramps complying with Section 11B-405, and required at stairs complying with Section 11B-504 shall comply...
-
11B-206.4.1 Entrances and exterior ground floor exits
Exits in excess of those required by Chapter 10, and which are more than 24 inches (610 mm) above grade shall not be required to comply with Section 11B-404....
-
11B-206.4.1 Entrances and exterior ground floor exits
Exits in excess of those required by Chapter 10, and which are more than 24 inches (610 mm) above grade shall not be required to comply with Section 11B-404....
-
11B-206.4.1 Entrances and exterior ground floor exits
Exits in excess of those required by Chapter 10, and which are more than 24 inches (610 mm) above grade shall not be required to comply with Section 11B-404....
-
§ 36.304(d)(3)
(3) If, as a result of compliance with the alterations requirements specified in paragraph (d)(1) and (d)(2) of this section, the measures required to remove a barrier would not be readily...
-
402.4 Characters (Section-by-Section Analysis)
402.4 Characters (Section-by-Section Analysis) This section proposes to require that at least one mode of characters displayed on a screen be in sans serif font....
-
Identification [4.3.11.5]
The "AREA OF RESCUE ASSISTANCE" label and access symbol must be illuminated where fire or life safety codes require illuminated exit signs....
-
4.1.1(5)(a)
(a) In new construction, a person or entity is not required to meet fully the requirements of these guidelines where that person or entity can demonstrate that it is structurally impracticable...
-
F206.1 General
The final rule adds three exceptions to this section, which contains the scoping requirements for accessible routes....
- Corbin Russwin Inc. DC8000 Series Heavy-Duty Door Closer
- Whitehall Mfg. WH2125A On-Floor Bariatric Stainless Steel Toilet
- Listen Technologies ADA Standard Stationary IR Assistive Listening System
- Allegion Schlage LT Series Mechanical Locks with Tubular Interconnect
- DORMA 8900 Series Door Closer
-
2.6 Communications.
Airports are required to take appropriate steps to ensure that their communications with individuals with disabilities are as effective as communications with other individuals, beneficiaries...
-
Number of Accessible Bathrooms
Other commenters recommended that only one full bathroom be required to be made accessible....
-
Subpart D -- New Construction and Alterations (Section-By-Section Analysis and Response to Comments)
This requirement contemplates a high degree of convenient access....
-
11B-404.2.3 Clear width
There shall be no projections into the required clear opening width lower than 34 inches (864 mm) above the finish floor or ground....
-
11B-604.8.2.2 Doors
Toilet compartment doors shall not swing into the minimum required compartment area. [2010 ADA Standards] 604.8.2.2 Doors....
-
11B-404.2.11 Vision lights
Exception: Glazing panels with the lowest part more than 66 inches (1676 mm) from the finish floor or ground shall not be required to comply with Section 11B-404.2.11....
-
11B-228.2 Mail boxes
residential facilities, where mail boxes are provided for each residential dwelling unit, mail boxes complying with Section 11B-309 shall be provided for each residential dwelling unit required...
-
General: ADA Standard Section 224.1
Section 224.1 of the ADA Standards covers information in the current ADA Standards on scoping requirements for transient lodging guest rooms.