206.2.8 Employee Work Areas
-
Doors: ADA Standard Section 604.8.1.2
Section 604.8.1.2 covers the current ADA Standards for wheelchair accessible compartment doors.
-
11B-307.2 Protrusion limits
Exception: Handrails shall be permitted to protrude 4½ inches (114 mm) maximum. Advisory 11B-307.2 Protrusion limits....
-
11B-1009.5.7 Grab bars
Exception: Grab bars on transfer systems shall not be required to comply with Section 11B-609.4....
-
11B-1009.5.7 Grab bars
Exception: Grab bars on transfer systems shall not be required to comply with Section 11B-609.4....
-
11B-307.2 Protrusion limits
Exception: Handrails shall be permitted to protrude 4½ inches (114 mm) maximum. Advisory 11B-307.2 Protrusion limits....
-
11B-705.1.2.2.2.1 One entrance/exit point
Exceptions: 1....
-
11B-407.3.4 Door and signal timing
Exceptions: For cars with in-car lanterns, T shall be permitted to begin when the signal is visible from the point 60 inches (1524 mm) directly in front of the farthest hall call button...
-
11B-407.3.4 Door and signal timing
Exceptions: For cars with in-car lanterns, T shall be permitted to begin when the signal is visible from the point 60 inches (1524 mm) directly in front of the farthest hall call button...
-
11B-703.4.1 Height above finish floor or ground
Exception: Tactile characters for elevator car controls shall not be required to comply with Section 11B-703.4.1....
-
11B-404.3.2 Maneuvering clearance
Exception: Where automatic doors and gates remain open in the power-off condition, compliance with Section 11B-404.2.4 shall not be required....
-
1009.6.3 Size
Exception: The enforcing agency may reduce the size of each required area of refuge to accommodate one wheelchair space that is not less than 30 inches by 52 inches (762 mm by 1320 mm) on...
-
406.2.2 Clear height
Exception: A lower clear height is permitted for a parking tier in mechanical-access open parking where approved by the building official. Advisory 406.2.2 Clear height....
-
11B-206.4.1 Entrances
ETA Editor's Note From DSA's "Summary of 2022 California Building Code Changes for Accessibility in the Triennial Code Cycle": "Code amendment relocates Exceptions 1 and 2 (relating to...
-
11B-705.1.1.2 Dome spacing
Exception: Where installed in a radial pattern, truncated domes shall have a center-to-center spacing of 1.6 inches (41 mm) minimum to 2.4 inches (61 mm) maximum....
-
Within a Site: ADA Standard Section 206.2.2
Section 206.2.2 covers the scoping requirements for accessible routes within a site in the most current ADA Standards.
-
Designations: ADA Standard Section 216.2
Section 216.2 covers scoping requirements in the current ADA Standards for sign designations.
-
Car Dimensions and Doors: ADA Standard Section 408.4.1
Section 408.4.1 covers the current ADA Standards for the car dimensions and doors of limited-use/limited-application elevators.
-
Toe Clearance: ADA Standard Section 604.8.1.4
Section 604.8.1.4 covers the current ADA Standards for toe clearance at wheelchair accessible compartments.
-
Grab Bars: ADA Standard Section 1009.5.7
EXCEPTION: Grab bars on transfer systems shall not be required to comply with 609.4....
-
11B-404.3.2 Maneuvering clearance
Exception: Where automatic doors and gates remain open in the power-off condition, compliance with Section 11B-404.2.4 shall not be required....
-
11B-703.4.1 Height above finish floor or ground
Exception: Tactile characters for elevator car controls shall not be required to comply with Section 11B-703.4.1....
-
11B-1009.2.1 Pool lift location
Exceptions: 1. Where the entire pool depth is less than 36 inches (914 mm) or greater than 48 inches (1219 mm), compliance with Section 11B-1009.2.1 shall not be required....
-
1009.6.3 Size
Exception: The enforcing agency may reduce the size of each required area of refuge to accommodate one wheelchair space that is not less than 30 inches by 52 inches (762 mm by 1320 mm) on...