Section 604.8.1.1 covers the current ADA Standards for the size of wheelchair accessible compartments.
Search Results "Clear Space"
-
Size: ADA Standard Section 604.8.1.1
- Phonic Ear HearIt Media Wireless Amplifier for Televisions and Mobile Telephones
- Activar JL Industries Ambassador Series 1017F10 Steel Fire Extinguisher Cabinets
-
MEZZANINE
[DSA-AC] An intermediate level or levels between the floor and ceiling of any story with an aggregate floor area of not more than one-third of the area of the room or space in which the...
-
MEZZANINE
[DSA-AC] An intermediate level or levels between the floor and ceiling of any story with an aggregate floor area of not more than one-third of the area of the room or space in which the...
- Wikk Industries Ingress'r Automatic Door Control
-
11B-405.7.4 Change in direction
Ramps that change direction between runs at landings shall have a clear landing 60 inches (1525 mm) minimum by 72 inches (1829 mm) minimum in the direction of downward travel from the upper...
-
11B-405.7.4 Change in direction
Ramps that change direction between runs at landings shall have a clear landing 60 inches (1525 mm) minimum by 72 inches (1829 mm) minimum in the direction of downward travel from the upper...
- Inclusion Solutions Paint Marking Stick
- Gamco Automatic Wall-Mounted Foam Soap Dispenser - G-950FA
-
11B-208.3.2 Residential facilities
dwelling units required to provide mobility features complying with Sections 11B-809.2 through 11B-809.4, and adaptable features complying with Sections 11B-809.6 through 11B-809.12 parking spaces...
-
11B-208.3.2 Residential facilities
dwelling units required to provide mobility features complying with Sections 11B-809.2 through 11B-809.4, and adaptable features complying with Sections 11B-809.6 through 11B-809.12 parking spaces...
- Accessible Mats for Beach and Outdoor Events
-
810.2.2 Dimensions--Modification to 810.2.2 of Appendix D to 36 CFR Part 1191
810.2.2 Dimensions--Modification to 810.2.2 of Appendix D to 36 CFR Part 1191 Bus boarding and alighting areas shall provide a clear length of 96 inches (2440 mm), measured perpendicular...
-
Findings
However, the design may not have allocated for the 30 x 48 inch clear floor space to transfer at the swing or the required 60 inch diameter turning space adjacent to the swing. ...
-
1134A.6 Showers
A water closet may project a maximum of 12 inches (305 mm) into the opening, provided that a minimum of 36 inches (914 mm) clear space is maintained between the water closet and the shower...
-
Homeless Shelters, Group Homes, and Similar Social Service Establishments
In sleeping rooms with more than 25 beds that are covered by § 36.406(d) a minimum of five percent (5%) of the beds must have clear floor space compliant with section 806.2.3 of the 2010...
-
i. Medical examination and treatment tables and chairs
in the course of its enforcement efforts that medical and dental examination tables and chairs often are too high to be accessible, lack stabilization elements, and do not have adequate clear...
-
Getting From Here to There—Outdoor Recreation Access Routes
Design outdoor recreation access routes to meet technical requirements for running and cross slopes, resting intervals, surface, clear tread width, passing spaces, tread obstacles, protruding...
-
LULA Elevator Dimensions
The guidelines specify that LULA elevator cars be at least 42 inches wide and 54 inches deep with a door on the narrow end providing at least 32 inches clear width (408.4.1)....
- Pressalit Care PLUS Support Arm Fixed Height Swing Grab Bar
-
Automatic Door Break Out Openings
The 2010 Standards at sections 404.1, 404.3, 404.3.1, and 404.3.6 require automatic doors that are part of a means of egress and that do not have standby power to have a 32-inch minimum clear...
-
1132A.3 Width and height of interior doors and secondary exterior doors
Swinging doors shall provide a net clear opening width of not less than 32 inches (813 mm), measured with the door or doors positioned at an angle of 90 degrees from the closed position....
-
R210 Protruding Objects
Objects along or overhanging any portion of a pedestrian circulation path shall comply with R402 and shall not reduce the clear width required for pedestrian access routes....