1. Location. Vanities and lavatories shall be installed with the centerline of the fixture a minimum of 18 inches (457 mm) horizontally from an adjoining wall or fixture to allow for...
Search Results "Section 504"
-
1134A.8, Item 1
-
1134A.6, Item 1.2
1.2. The shower stall shall measure at least 30 inches deep by 60 inches wide (762 mm by 1524 mm) with an entrance opening of at least 60 inches (1524 mm). A water closet may project...
-
1134A.6, Item 3
3. Floor space. A clear maneuvering space at least 30 inches in width by 48 inches in length (762 mm by 1219 mm) shall be located outside the shower, flush and parallel to the...
-
1134A.8, Item 3
3. Cabinets. Cabinets under lavatories are acceptable provided the bathroom has space to allow a parallel approach by a person in a wheelchair and the lavatory cabinets are designed...
-
1134A.7, Item 4
4. Water closet controls. Water closet controls shall be mounted no more than 44 inches (1118 mm) above the floor. The force required to activate controls shall be no greater than 5...
-
1135A.1 General
If clothes washing machines and clothes dryers are provided in covered multifamily dwelling units, one of each type of appliance shall be provided. Where front-loading clothes...
-
11B-233.3.4.3 Alterations to residential dwelling units with adaptable features
The building standards for residential dwelling units with adaptable features do not apply to the alteration, repair, rehabilitation or maintenance of residential dwelling units...
-
1135A.1 General
If clothes washing machines and clothes dryers are provided in covered multifamily dwelling units, one of each type of appliance shall be provided. Where front-loading clothes...
-
§ 1194.1 Standards for Section 508 of the Rehabilitation Act.
The standards for information and communication technology developed, procured, maintained, or used by Federal agencies covered by Section 508 of the Rehabilitation Act are set forth in...
- HUD: Accessibility Requirements for Buildings
-
Cross Section of Gripping Surfaces
the following dimensions for grab bars to enable individuals with disabilities to firmly grasp the grab bars and support themselves during transfers: • Grab bars with circular cross sections...
-
Which accessibility guidelines must we use?
The 1973 law—Section 504 of the Rehabilitation Act — requires provision of equal opportunity for individuals with disabilities to participate in all Federal or federally-funded programs...
-
1134A.7 Water closets
Water closets in bathrooms or powder rooms required to be accessible shall comply with this section. 1. Floor space and location....
-
M305.2.4.2 Non-Circular Cross Section
Transfer supports with non-circular cross sections shall have a cross-section dimension of 2 inches (51 mm) maximum and a perimeter dimension of 4 inches (100 mm) minimum and 4.8 inches...
-
ADA & Level Boarding - Public Obligations
49 CFR 37.42(c); 49 CFR 27.7(b)(2) 5/24/12
-
36 CFR Part 1193 Telecommunications Act (Section 255) Accessibility Guidelines
ARCHITECTURAL AND TRANSPORTATION BARRIERS COMPLIANCE BOARD 36 CFR Part 1193 [Docket No. 97–1] RIN 3014–AA19 Telecommunications Act Accessibility Guidelines AGENCY:...
-
1134A.8, Item 4.3
The knee and toe space shall be centered on the fixture, and shall comply with Section 1138A.2....
-
1134A.8, Item 4.3
The knee and toe space shall be centered on the fixture, and shall comply with Section 1138A.2....
-
1132A.10 Door signal devices
1132A.10 Door signal devices. Every primary entrance to a covered multifamily dwelling unit shall be provided with a door buzzer, bell, chime or equivalent. The activating mechanism...
-
1132A.10 Door signal devices
Every primary entrance to a covered multifamily dwelling unit shall be provided with a door buzzer, bell, chime or equivalent. The activating mechanism shall be mounted a maximum of...
-
1132A.10 Door signal devices
Every primary entrance to a covered multifamily dwelling unit shall be provided with a door buzzer, bell, chime or equivalent. The activating mechanism shall be mounted a maximum of...
-
1. Transfer Supports
The Access Board received 31 comments to these questions and the MDE Advisory Committee made 10 recommendations regarding the transfer support section....
-
E202.7.2 Alternative Means
Where ICT that fully conforms to the Revised 508 Standards is not commercially available, the agency shall provide individuals with disabilities access to and use of information and...
-
E202.7.1 Required Documentation
The responsible agency official shall document in writing: (a) the non-availability of conforming ICT, including a description of market research performed and which provisions...