409.4.6.1 Size. Control buttons shall be 3/4 inch (19 mm) minimum in their smallest dimension.
Search Results "Private Building"
Commonly Searched Documents
-
409.4.6.1 Size
-
409.4.4 Leveling
409.4.4 Leveling. Each car shall automatically stop at a floor landing within a tolerance of ½ inch (13 mm) under rated loading to zero loading conditions.
-
409.4.6 Car Controls
409.4.6 Car Controls. Elevator car control buttons shall comply with 409.4.6, 309.3, 309.4, and shall be raised or flush.
-
409.3.2 Location
409.3.2 Location. Elevator car doors or gates shall be positioned at the narrow end of the clear floor spaces required by 409.4.1.
-
III-5.2000 Commercial facilities in a home
III−5.2000 Commercial facilities in a home. When a commercial facility, such as a home sales office or production workshop, is located in a home, the portion used exclusively as a...
-
11B-409.4.6.2 Location
Control panels shall be on a side wall, 12 inches (305 mm) minimum from any adjacent wall.
-
11B-409.4.4 Leveling
Each car shall automatically stop at a floor landing within a tolerance of ½ inch (12.7 mm) under rated loading to zero loading conditions.
-
11B-409.4.6.1 Size
Control buttons shall be ¾ inch (19.1 mm) minimum in their smallest dimension.
-
11B-409.3.2 Location
Elevator car doors or gates shall be positioned at the narrow end of the clear floor spaces required by Section 11B-409.4.1.
-
11B-409.4.6 Car controls
Elevator car control buttons shall comply with Sections 11B-409.4.6, 11B-309.3, 11B-309.4, and shall be raised or flush.
-
11B-409.4.1 Inside dimensions of elevator cars
Elevator cars shall provide a clear floor space of 36 inches (914 mm) minimum by 48 inches (1219 mm) minimum and shall comply with Section 11B-305.
-
§ 37.9(d)(1)(i)
(i)
-
11B-409.4.6.1 Size
Control buttons shall be ¾ inch (19.1 mm) minimum in their smallest dimension.
-
11B-409.4.4 Leveling
Each car shall automatically stop at a floor landing within a tolerance of ½ inch (12.7 mm) under rated loading to zero loading conditions.
-
11B-409.4.1 Inside dimensions of elevator cars
Elevator cars shall provide a clear floor space of 36 inches (914 mm) minimum by 48 inches (1219 mm) minimum and shall comply with Section 11B-305.
-
11B-409.4.6 Car controls
Elevator car control buttons shall comply with Sections 11B-409.4.6, 11B-309.3, 11B-309.4, and shall be raised or flush.
-
11B-409.3.2 Location
Elevator car doors or gates shall be positioned at the narrow end of the clear floor spaces required by Section 11B-409.4.1.
-
11B-409.4.6.2 Location
Control panels shall be on a side wall, 12 inches (305 mm) minimum from any adjacent wall.
-
§ 37.101 Purchase or lease of vehicles by private entities not primarily engaged in the business of transporting people
[56 FR 45621, Sept. 6, 1991, as amended at 61 FR 25416, May 21, 1996]
-
608.3 Grab Bars
Grab bars shall not be required to be installed in a shower located in a bathing facility for a single occupant accessed only through a private office, and not for common use or public use...
-
Example: Town Library is a Historic Property
architect to determine if an accessible entrance can be provided and is told that a ramp or lift cannot be added to either entrance without a significant change to the exterior of the building...
-
Sec.36.102(a)(3)
(3) Private entity that offers examinations or courses related to applications, licensing, certification, or credentialing for secondary or postsecondary education, professional, or trade...
-
Height: ADA Standard Section 1005.2.1
EXCEPTION: Where a guard complying with sections 1003.2.12.1 and 1003.2.12.2 of the International Building Code (2000 edition) or sections 1012.2 and 1012.3 of the International Building...
-
§ 37.183 Purchase or lease of new OTRBs by operators of fixed-route systems
The following requirements apply to private entities that are primarily in the business of transporting people, whose operations affect commerce, and that operate a fixed-route system...