A sign complying with Section 11B-703.5 shall be posted in a conspicuous place at each landing and within the platform, enclosure stating “No Freight” and include the International Symbol...
Search Results "Landing"
-
11B-410.8 Restriction sign
- Aluminum Heavy Duty Wheels n' Heels® InVent Grating
-
11B-505.10.2 Top extension at stairs
At the top of a stair flight, handrails shall extend horizontally above the landing for 12 inches (305 mm) minimum beginning directly above the first riser nosing....
-
Transition Plates
Gangways are not required to have landings at the end, if transition plates are provided....
-
505.10.1 Top and Bottom Extension at Ramps
Ramp handrails shall extend horizontally above the landing for 12 inches (305 mm) minimum beyond the top and bottom of ramp runs....
-
Transition Plates
Gangways are not required to have landings at the end, if transition plates are provided....
-
505.10.1 Top and Bottom Extension at Ramps
Ramp handrails shall extend horizontally above the landing for 12 inches (305 mm) minimum beyond the top and bottom of ramp runs....
-
505.10.2 Top Extension at Stairs
At the top of a stair flight, handrails shall extend horizontally above the landing for 12 inches (305 mm) minimum beginning directly above the first riser nosing....
-
Doors and Gates: ADA Standard Section 410.6
Section 410.6 covers the current ADA Standards for the doors and gates of platform lifts.
-
CIRCULATION PATH
exterior or interior way of passage provided for pedestrian travel, including but not limited to, walks, sidewalks, hallways, courtyards, elevators, platform lifts, ramps, stairways and landings...
-
CIRCULATION PATH
exterior or interior way of passage provided for pedestrian travel, including but not limited to, walks, sidewalks, hallways, courtyards, elevators, platform lifts, ramps, stairways and landings...
-
1009.7.2 Separation
The fire-resistance-rated exterior wall construction shall extend horizontally 10 feet (3048 mm) beyond the landing on either side of the landing or equivalent fire-resistance-rated construction...
-
505.10.2 Top Extension at Stairs
At the top of a stair flight, handrails shall extend horizontally above the landing for 12 inches (305 mm) minimum beginning directly above the first riser nosing....
-
6d. Ramp Length
If a ramp is more than 30 feet long, is a level landing at least 60 inches long provided every 30 feet of horizontal length?...
- Aluminum Heavy Duty Wheels n' Heels® Metro Grating
-
11B-410.6 Doors and gates
Exception: Platform lifts serving two landings maximum and having doors or gates on opposite sides shall be permitted to have self-closing manual doors or gates....
-
11B-410.6 Doors and gates
Exception: Platform lifts serving two landings maximum and having doors or gates on opposite sides shall be permitted to have self-closing manual doors or gates....
-
1007.7.4 Separation
The fire-resistance-rated exterior wall construction shall extend horizontally 10 feet (3048 mm) beyond the landing on either side of the landing or equivalent fire-resistance-rated construction...
-
Re: 405 Ramps
A ramp with a direction change requires a 60" x 60" minimum intermediate landing, which isn't just a turning space but also a place for stopping to allow for a turn....
-
NOSING
The leading edge of treads of stairs and of landings at the top of stairway flights....
-
NOSING
The leading edge of treads of stairs and of landings at the top of stairway flights....
- Adaptive Surfing Makes the Ocean Accessible for People Who Use Wheelchairs - Rolling On, Episode 5
-
NOSING
The leading edge of treads of stairs and of landings at the top of stairway flights....
-
R407.7 Surfaces
Surfaces of ramp runs and landings shall comply with R302.7....