1.9.1.2.2 Any sanitary facilities which are made available for the public, clients or employees in such accommodations or facilities.
Search Results "Guest Bathroom"
-
1.9.1.2.2
-
11B-213.1 General
Where toilet facilities and bathing facilities are provided, they shall comply with Section 11B-213. Where toilet facilities and bathing facilities are provided in facilities...
-
11B-603.2 Clearances
Clearances shall comply with Section 11B-603.2.
-
11B-213.1 General
Where toilet facilities and bathing facilities are provided, they shall comply with Section 11B-213. Where toilet facilities and bathing facilities are provided in facilities...
-
1.9.1.2.2
1.9.1.2.2 Any sanitary facilities which are made available for the public, clients or employees in such accommodations or facilities.
-
213.1 General
Where toilet facilities and bathing facilities are provided, they shall comply with 213. Where toilet facilities and bathing facilities are provided in facilities permitted by...
-
213.1 General
213.1 General. Where toilet facilities and bathing facilities are provided, they shall comply with 213. Where toilet facilities and bathing facilities are provided in facilities...
-
11B-229.1 General
Glazed openings in guest rooms required to provide communication features and in guest rooms required to comply with Section 11B-206.5.3 shall not be required to comply with Section 11B-...
-
18(a)
Nothing in this subparagraph requires a hotel to have more accessible guest rooms than are required under ADA Standards §9.1.2....
-
11B-233.3.1.2.5 Multi-story residential dwelling units in buildings with no elevator
At least one powder room or bathroom shall be located on the primary entry level....
-
11B-233.3.1.2.5 Multi-story residential dwelling units in buildings with no elevator
At least one powder room or bathroom shall be located on the primary entry level....
-
Single User Restroom Accessibility
As a CASp or Accessibility consultant, you probably find yourself navigating between the requirements of the ADA Standards, the California Building Code, and legislative requirements...
-
11B-233.3.1.2.4 Multi-story residential dwelling units in buildings with one or more elevators
At least one powder room or bathroom and kitchen shall be located on the primary entry level....
-
11B-233.3.1.2.4 Multi-story residential dwelling units in buildings with one or more elevators
At least one powder room or bathroom and kitchen shall be located on the primary entry level....
-
11B-233.3.4.2 Alterations to individual residential dwelling units
In individual residential dwelling units, where a bathroom or a kitchen is substantially altered, and at least one other room is altered, the requirements of Section 11B-233.3.1 shall apply...
-
11B-233.3.4.2 Alterations to individual residential dwelling units
In public housing facilities with individual residential dwelling units, where a bathroom or a kitchen is substantially altered, and at least one other room is altered, the requirements...
-
25.1 Q. It appears from Figure 2(c) of the Guidelines (under Requirement 5) that there is a 34 inch height requirement for kitchen counters and vanities. Is this true?
Requirement 7 addresses the requirement for usable kitchens and bathrooms so that a person in a wheelchair can maneuver about the space....
-
28.1 Q. If an architect or builder chooses to follow the bathroom specifications in Requirement 7...are the other bathrooms in the dwelling unit required to have reinforced walls for grab bars?
Requirement 6 of the Guidelines requires reinforced walls in bathrooms for later installation of grab bars....
-
Section 36.406(e) Housing at a Place of Education (Section-by-Section Analysis)
be served by bathrooms with roll-in showers....
-
Shower and Sauna Doors in Transient Lodging Facilities
Section 9.4 of the 1991 Standards and section 206.5.3 of the 2010 Standards both require passage doors in transient lodging guest rooms that do not provide mobility features to provide at...
-
11B-806.3.2 Notification devices
Visible notification devices shall be provided to alert room occupants of incoming telephone calls and a door knock or bell. Notification devices shall not be connected to visible...
-
11B-806.3.1 Alarms
Where emergency warning systems are provided, fire alarms shall comply with Section 11B-702 and carbon monoxide alarms shall comply with Chapter 4. [2010 ADA Standards] 806.3.1...
-
11B-806.3.2 Notification devices
Visible notification devices shall be provided to alert room occupants of incoming telephone calls and a door knock or bell. Notification devices shall not be connected to visible...
-
11B-806.3.1 Alarms
Where emergency warning systems are provided, fire alarms shall comply with Section 11B-702 and carbon monoxide alarms shall comply with Chapter 4. [2010 ADA Standards] 806.3.1...