This section requires the running slope of any segment of an outdoor recreation access route to not be steeper than 1:10 (10%). Where the running slope of a segment of an outdoor...
Search Results "Grade Level Exit"
Commonly Searched Documents
-
1016.7.1 Maximum Running Slope and Segment Length
-
18. In § 38.125, amend the first sentence of paragraph (a)(2)
In § 38.125, amend the first sentence of paragraph (a)(2) by adding the words “level-entry boarding,” before the words ” portable or platform lifts” and by adding a second sentence “The...
-
Additional Design Specifications for Requirement 1
Finally, the Guidelines provide that if the slope of the finished grade between covered multifamily dwellings and a public or common use facility exceeds 8.33%, or where other physical barriers...
-
§ 38.159(a)(1) General
All vehicles covered by this subpart shall provide a level-change mechanism or boarding device (e.g., lift or ramp) complying with paragraph (b) or (c) of this section and sufficient clearances...
-
404.2.5 Thresholds
Raised thresholds and changes in level at doorways shall comply with 302 and 303....
-
404.2.5 Thresholds
Raised thresholds and changes in level at doorways shall comply with 302 and 303....
-
Are doors or gates to employee work areas required to comply?
Areas used only by employees as work areas must provide access for approach, entry, and exit, including means of egress....
-
404.2.5 Thresholds
Raised thresholds and changes in level at doorways shall comply with 302 and 303....
-
1003.2.13.5 Areas of refuge
used as an area of refuge, the shaft and lobby shall comply with Section 1005.3.2.5 for smokeproof enclosures except where the elevators are in an area of refuge formed by a horizontal exit...
-
11B-1008.2.1 Ground level and elevated play components
Accessible routes serving ground level play components and elevated play components shall be permitted to use the exceptions in Section 11B-1008.2.1....
-
11B-1008.2.1 Ground level and elevated play components
Accessible routes serving ground level play components and elevated play components shall be permitted to use the exceptions in Section 11B-1008.2.1. Exceptions: 1. ...
-
11B-1008.2.1 Ground level and elevated play components
Accessible routes serving ground level play components and elevated play components shall be permitted to use the exceptions in Section 11B-1008.2.1. Exceptions: 1....
-
Thresholds at Doorways [4.13.8]
Negotiating level changes while simultaneously resisting the force of closers can be difficult....
- Figure 703.3.1 Braille Measurement – Drawing from the U.S. Access Board
-
Step 2: Identify the Presence of Limiting Factors
Does the combined trail running slope (grade) and cross slope exceed 1:2.5 (40 percent) for a continuous distance of 20 feet (6 meters) or more?...
-
11B-404.2.4.4 Floor or ground surface
Changes in level, slopes exceeding 1:48, and detectable warnings shall not be permitted. Exceptions: Reserved....
-
1003.2.13.7
[See subsections ...]
-
207 Accessible Means of Egress
207 Accessible Means of Egress
-
Areas of Rescue Assistance [4.1.3(9), 4.3.11]
sprinkler systems, “which are systems with built-in signals used to monitor system features (the opening and closing of water control valves, the power supplies of needed pumps, water tank levels...
-
4.28.2* Audible Alarms
If provided, audible emergency alarms shall produce a sound that exceeds the prevailing equivalent sound level in the room or space by at least 15 dbA or exceeds any maximum sound level...
-
4.28.2* AUDIBLE ALARMS
If provided, audible emergency alarms shall produce a sound that exceeds the prevailing equivalent sound level in the room or space by at least 15 decibels or exceeds any maximum sound level...
-
Egress [4.1.3(9), 4.3.10]
Accessible means of egress are required according to the number of exits provided to meet the building or life safety code....
-
Ground Level: ADA Standard Section 1008.2.4.1
At ground level, the clear width of accessible routes shall be 60 inches (1525 mm) minimum. EXCEPTIONS: 1....
-
E1-2. Accessible Route
Is the accessible route free of steps and abrupt level changes over 1/2 inch (level changes between 1/4 inch and 1/2 inch should be beveled)?...