Re: DSA Drawing 11B-406-1C Curb Ramp Adjoining a Parking Access Aisle next to a Curb and Gutter (2016 CBC)
This drawing should show that the gutter is not included in the required min 18’ depth. The dashed lines don’t spell it out clearly enough to me.
-
Re: DSA Drawing 11B-406-1C Curb Ramp Adjoining a Parking Access Aisle next to a Curb and Gutter (2016 CBC)
Interesting issue/drawing. If the slope of the gutter is greater than 1:48, can they merely show it outside of the required 18' deep accessible parking space and access aisle? If...
-
DSA Drawing 11B-406-10C Curb Ramp Adjoining a Parking Access Aisle with No Gutter (2016 CBC)
Requires the Premium User plan or above. (Login or upgrade your account!)
-
DSA Drawing 11B-406.6-6 Raised Island with No Gutters (2016 CBC)
Requires the Premium User plan or above. (Login or upgrade your account!)
-
DSA Drawing 11B-406-9C Curb Ramp Adjoining a Parking Access Aisle next to a Curb and Gutter (2016 CBC)
Requires the Premium User plan or above. (Login or upgrade your account!)
- TownSteel TRXL Grade 1 Cylindrical Lock with Ligature Resistant Trim
- Tobii PCEye Go Video 2 - Mounting
-
11B-411.2.3.1 Floor designation signs
Signs shall be provided in both raised characters and Braille. Raised characters shall be 2 inches (51 mm) high....
-
11B-411.2.3.1 Floor designation signs
Signs shall be provided in both raised characters and Braille. Raised characters shall be 2 inches (51 mm) high....
- TownSteel MRXL Grade 1 Mortise lock with Ligature Resistant Escutcheon
- TownSteel MRXA Grade 1 Mortise Lock with Ligature Resistant Trim
- Hager Companies 3800 Series - Grade 1 Mortise (Sectional)
- TownSteel CE/CEC Series, Grade 1, Heavy Duty Cylindrical Locks
- Stanley QCL 100 Series Grade 1 Heavy Duty Cylindrical Locks
-
5.2 Q. If a building design contains a mix of single-story flats on grade and single-story flats located above grade over a public parking area, do the flats over the parking area have to be accessible?
In the example in the above question, because some single-story flats are situated on grade, these flats would be the ground floor dwelling units and would be required to be accessible....
- Cal-Royal Products Grade 1 Cylindrical Lockset Calypso CAL Series
-
4.10.4(2)
(2) Visual elements shall be at least 2‒1/2 in (64 mm) in the smallest dimension....
-
DSA Drawing 11B-406-3C Curb Ramp Adjoining a Parking Access Aisle next to a Curb and Gutter (2016 CBC)
Requires the Premium User plan or above. (Login or upgrade your account!)
-
DSA Drawing 11B-406.6-5 Raised Island next to Curbs and Gutters (2016 CBC)
Requires the Premium User plan or above. (Login or upgrade your account!)
-
DSA Drawing 11B-406.6-1 Raised Island next to Curbs and Gutters (2016 CBC)
Requires the Premium User plan or above. (Login or upgrade your account!)
-
DSA Drawing 11B-406-8 Parallel Curb Ramp with No Gutter (2016 CBC)
Requires the Premium User plan or above. (Login or upgrade your account!)
-
STEP 2
STEP 2 Determining what is needed based on Table 240.2.1.2: Table 240.2.1.2 Number of elevated play components provided Minimum number of ground-level play components...