Reading and Study Areas [8.2]
-
11B-809.10.6.2 Slope
The slope of the shower floor shall be 1/2 inch (12.7 mm) per foot maximum in any direction and shall slope to a drain....
-
Spacing: ADA Standard Section 609.3
Section 609.3 covers the current ADA Standards for the grab bar spacing between the wall, objects above, below and at the ends of the grab bar.
-
11B-610.3.1 Rectangular seats
FIGURE 11B-610.3.1 RECTANGULAR SHOWER SEAT...
-
610.3.1 Rectangular Seats
Figure 610.3.1 Rectangular Shower Seat...
-
610.3.1 Rectangular Seats
Figure 610.3.1 Rectangular Shower Seat...
-
Trip-by-Trip Eligibility
Eligibility does not inhere in the individual or his or her disability, as such, but in meeting the functional criteria of inability to use the fixed route system established by the ADA....
-
11B-608.3.1 Reserved
11B-608.3.1 Reserved.
-
4.21.4 Grab Bars
ADAAG specifies grab bars on the three walls of a roll-in shower stall, 33"-36" above the floor. The plans reviewed offered little insight as to placement of grab bars in showers....
-
5.3.3 Seats
Pit toilet seats shall comply with 5.3.3.
-
§ 37.139 Plan contents
Each plan shall contain the following information:
-
§ 37.135 Submission of paratransit plan
[56 FR 45621, Sept. 6, 1991, as amended at 61 FR 25416, May 21, 1996; 61 FR 26468, May 28, 1996; 79 FR 21406, Apr. 16, 2014]
-
Pool Lifts
Pool Lifts Pool lifts must be located where the water level is not deeper than 48 inches. This provides the opportunity for someone to provide assistance from a standing position...
-
Seat Height
Seat Height The lift must be designed so that the seat will make a stop between a minimum of 16 inches and maximum of 19 inches (measured from the deck to the top of the seat...
-
Submerged Depth
Submerged Depth Lifts must be designed so that the seat will submerge to a minimum of 18 inches below the stationary water level. This will ensure buoyancy for the person on the...
-
Lifting Capacity
Lifting Capacity Lifts must have the capability of supporting a minimum weight of 300 pounds and be capable of sustaining a static load that is at least 1.5 times the rated load....
-
CHAPTER 9: BUILT-IN ELEMENTS
CHAPTER 9: BUILT-IN ELEMENTS
- Redi Free® with Redi Base® Shower Pans
- Redi Free® with Redi Trench® Shower Pans
- Proline Drain: Quick Drain USA - Structural Panel Tub to Shower Conversion
-
1016.9 Protruding Objects
Constructed elements on outdoor recreation access routes, passing spaces, and resting intervals shall comply with 307. Advisory 1016.9 Protruding Objects. Protruding objects on...
-
Question 7
YES/NO 7. Are all sidewalks and walkways to the business entrance free of any objects (e.g., overhanging trees, flags, hanging planters) with bottom...
-
1017.9 Protruding Objects
Constructed elements on trails, passing spaces, and resting intervals shall comply with 307. Advisory 1017.9 Protruding Objects. Protruding objects on trails, passing spaces, and...
-
1016.9 Protruding Objects
Constructed elements on outdoor recreation access routes, passing spaces, and resting intervals shall comply with 307. Advisory 1016.9 Protruding Objects. Protruding objects on...