Identification Signs" referenced in CBC 11B-504.8 and in the second paragraph (only) of 1023.9 should not be confused with the "Stairway Identification Signs" (hereinafter termed the "Fire...
Search Results "Fire Tower"
Commonly Searched Documents
-
11B-504.8 Floor identification
-
Current Accessibility Guidelines That Apply to the Forest Service
fishing facilities, including: Boating facilities Docks Fishing piers and platforms New or reconstructed: Picnic areas Fire...
-
Prohibited Use: ADA Standard Section 809.5.4
Visible alarm appliances used to indicate residential dwelling unit smoke detection or building fire alarm activation shall not be used for any other purpose within the residential dwelling...
-
1023.9 Stairway identification signs
"Floor Identification Signs" referenced in CBC 11B-504.8 and in the second paragraph only of 1023.9 should not be confused with the "Stairway Identification Signs" (hereinafter termed "Fire...
-
III-7.3130 General exceptions
This includes elevator pits, elevator penthouses, piping or equipment catwalks, cooling towers, and utility tunnels....
-
101.4.4 Property maintenance
The provisions of the California Existing Building Code shall apply to existing structures and premises; equipment and facilities; light, ventilation, space heating, sanitation, life and fire...
-
When is a historic structure considered accessible?
The fundamental program offered at the lighthouse is the interpretation of the area's history and culture, as well as a great view from the top of the light tower....
-
1009.7.2 Separation
Exterior walls separating the exterior area of assisted rescue from the interior of the building shall have a minimum fire-resistance rating of 1 hour, rated for exposure to fire from the...
-
1009.7.2 Separation
Exterior walls separating the exterior area of assisted rescue from the interior of the building shall have a minimum fire-resistance rating of 1 hour, rated for exposure to fire from the...
-
I. Public Toilet Rooms
Public Toilet Rooms: (1) In all public and common use toilet rooms throughout the Hotel and the Tower, Defendants will provide at least one lavatory with a counter-top that is 34 inches...
-
1007.7.4 Separation
Exterior walls separating the exterior area of assisted rescue from the interior of the building shall have a minimum fire-resistance rating of 1 hour, rated for exposure to fire from the...
-
907.5.2.3 Visible alarms
Exceptions: In other than Group I-2 and I-2.1, visible alarm notification appliances are not required in alterations, except where an existing fire alarm system is upgraded or replaced...
-
1.1.5 Referenced codes
The National Fire Codes, standards, and the Fire Protection Handbook of the National Fire Protection Association are permitted to be used as authoritative guides in determining recognized...
-
1.1.5 Referenced codes
The National Fire Codes, standards, and the Fire Protection Handbook of the National Fire Protection Association are permitted to be used as authoritative guides in determining recognized...
-
903.3.1.1.1 Exempt locations
Sprinklers shall not be omitted from any room merely because it is damp, of fire-resistance-rated construction or contains electrical equipment....
-
1.1.5 Referenced codes
The National Fire Codes, standards, and the Fire Protection Handbook of the National Fire Protection Association are permitted to be used as authoritative guides in determining recognized...
-
711.3.3 Ducts and air transfer openings
Penetrations of fire-resistance-rated walls by ducts and air transfer openings that are not protected with fire dampers shall comply with this section....
-
EXHIBIT A Required Accessible Elements at QuikTrip Stores
1. Accessible Routes. Accessible routes shall be provided in compliance with ADA Standards §§ 4.1.2(1), 4.1.3(1), and 4.3, including the following requirements: a. At least...
-
704.10 Vertical exposure
protectives shall be provided in every opening that is less than 15 feet (4572 mm) vertically above the roof of an adjoining building or adjacent structure that is within a horizontal fire...
-
4.3.11.1(3)
(3) A portion of a one-hour fire-resistive corridor (complying with local requirements for fire-resistive construction and for openings) located immediately adjacent to an exit enclosure...
-
Horizontal Exits [IBC §1021 (2003), §1005.3.5 (2000)]
A horizontal exit compartmentalizes a building allowing occupants to exit the area containing the origin of a fire into another portion of the building that is protected by fire-resistance-rated...
-
711.3.1 Through penetrations
Through penetrations of fire-resistance-rated walls shall comply with Section 711.3.1.1 or 711.3.1.2....
-
704.8.2 First story
In occupancies other than Group H, unlimited unprotected openings are permitted in the first story of exterior walls facing a street that have a fire separation distance of greater than...
-
711.4.2 Membrane penetrations
Penetrations of membranes that are part of a fire-resistance-rated horizontal assembly shall comply with Section 711.4.1.1 or 711.4.1.2....