STONE LEG PICNIC TABLE Contact Santa Fe NE for construction drawings ETA Editor's Note Stone Leg Picnic Table drawings: Click here to view/download CAD file | Click...
Search Results "Adult Changing Table"
-
Stone Leg Picnic Table
-
Steel Leg Picnic Table
STEEL LEG PICNIC TABLE Contact Santa Fe NE for construction drawings ETA Editor's Note Steel Leg Picnic Table drawings: Click here to view/download CAD file | Click...
-
C1-d
Is the accessible route free of steps and abrupt level changes higher than 1/2 inch?...
-
11B-246.5 Picnic areas
Where picnic tables are provided, at least one picnic table, and one additional table for each 20 tables or fraction thereof, shall be accessible and comply with Section 11B-902....
-
11B-246.5 Picnic areas
Where picnic tables are provided, at least one picnic table, and one additional table for each 20 tables or fraction thereof, shall be accessible and comply with Section 11B-902 _|Dining...
-
11B-246.5 Picnic areas
Where picnic tables are provided, at least one picnic table, and one additional table for each 20 tables or fraction thereof, shall be accessible and comply with Section 11B-902 _|Dining...
- Mockett TLRAL27 Roma Series Adjustable Table Leg
-
In a doctor’s office or clinic with multiple exam rooms, must every examination room have an accessible exam table and sufficient clear floor space next to the exam table?
Q In a doctor’s office or clinic with multiple exam rooms, must every examination room have an accessible exam table and sufficient clear floor space next to the exam table?...
- Smith System Husky Square Activity Table
-
405.7.1 Slope
Changes in level are not permitted. EXCEPTION: Slopes not steeper than 1:48 shall be permitted....
-
405.7.1 Slope
Changes in level are not permitted. EXCEPTION: Slopes not steeper than 1:48 shall be permitted....
-
902.2 Clear Floor or Ground Space
902.2 Clear Floor or Ground Space. A clear floor space complying with 305 positioned for a forward approach shall be provided. Knee and toe clearance complying
-
11B-902.2 Clear floor or ground space
A clear floor space complying with Section 11B-305 positioned for a forward approach shall be provided. Knee and toe clearance complying with Section 11B-306 shall be provided.
-
902.2 Clear Floor or Ground Space
A clear floor space complying with 305 positioned for a forward approach shall be provided. Knee and toe clearance complying with 306 shall be provided.
-
902.2 Clear Floor or Ground Space
A clear floor space complying with 305 positioned for a forward approach shall be provided. Knee and toe clearance complying with 306 shall be provided.
-
11B-902.2 Clear floor or ground space
A clear floor space complying with Section 11B-305 positioned for a forward approach shall be provided. Knee and toe clearance complying with Section 11B-306 shall be provided.
-
11B-902.2 Clear floor or ground space
A clear floor space complying with Section 11B-305 positioned for a forward approach shall be provided. Knee and toe clearance complying with Section 11B-306 shall be provided.
-
405.7.1 Slope
Changes in level are not permitted. EXCEPTION: Slopes not steeper than 1:48 shall be permitted....
-
11B-405.7.1 Slope
Changes in level are not permitted. Exception: Slopes not steeper than 1:48 shall be permitted....
-
11B-405.7.1 Slope
Changes in level are not permitted. Exception: Slopes not steeper than 1:48 shall be permitted....
- Segno ADA Table #3521
-
1131A.1 Changes in level not exceeding ½ inch
1131A.1 Changes in level not exceeding ½ inch. Abrupt changes in level along any accessible route shall not exceed ½ inch (12.7 mm)....
-
11B-405.4 Floor or ground surfaces
Changes in level other than the running slope and cross slope are not permitted on ramp runs....
-
11B-405.4 Floor or ground surfaces
Changes in level other than the running slope and cross slope are not permitted on ramp runs....