LaCantina Doors completely transforms and creates open spaces by removing the distinction between the indoors and outdoors....
Search Results "Transfer Space"
- LaCantina Doors
-
M305.3 Standing Supports (Section-by-Section Analysis)
Unlike transfer supports, standing supports can be horizontal or vertical and thus there will be variations in the configuration of standing supports dependent on the equipment configuration...
-
Tent Pads and Tent Platforms
Provide a minimum 48-inch (1,220-millimeter) clear floor or ground space on all sides of tents on tent pads and platforms that are required to be accessible....
-
Accessible parking requirements for Stadiums
how to calculate the number of required accessible parking spaces and van-accessible parking spaces for high school sports fields...
-
Co-sharing of Accessible Parking access Aisles by adjacent elevator door allowed?
Given: multistory parking structure circa 1980 with limited head height for vans Issue: Can an elevator door open to and co-share/use an access aisle for an accessible parking  space?...
-
11B-904.4.2 Forward approach
Knee and toe space complying with Section 11B-306 shall be provided under the counter....
-
11B-904.4.2 Forward approach
Knee and toe space complying with Section 11B-306 shall be provided under the counter....
-
Exception for accessible means of egress in existing buildings in IBC 2000
Accessible spaces shall be provided with not less than one accessible means of egress....
-
Trail Facilities
of this guidebook, this can be accomplished by ensuring the camp shelter floor is 17 inches (430 millimeters) minimum to 19 inches (485 millimeters) maximum higher than the camp shelter space...
-
11B-226.2 Dispersion
Dining surfaces required to comply with Section 11B-902 shall be dispersed throughout the space or facility containing dining surfaces for each type of seating in a functional area....
-
11B-226.2 Dispersion
Dining surfaces required to comply with Section 11B-902 shall be dispersed throughout the space or facility containing dining surfaces for each type of seating in a functional area....
- Irwin Seating Company ADA Swing-Away Aisle Panels
-
11B-216.2 Designations
Interior and exterior signs identifying permanent rooms and spaces shall comply with Sections 11B-703.1, 11B-703.2, 11B-703.3, and 11B-703.5....
-
11B-216.2 Designations
Interior and exterior signs identifying permanent rooms and spaces shall comply with Sections 11B-703.1, 11B-703.2, 11B-703.3, and 11B-703.5....
-
3.3 Data Sources
Early on, it became clear that some Committee members were unfamiliar with issues raised during transfers from a wheelchair or scooter onto a surface such as an examination table....
-
11B-903.4 Back support
To assist in transferring to the bench, consider providing grab bars on a wall adjacent to the bench, but not on the seat back....
-
11B-903.4 Back support
To assist in transferring to the bench, consider providing grab bars on a wall adjacent to the bench, but not on the seat back....
-
11B-213.3.6 Bathing facilities
Transfer type shower compartments shall be permitted in transient lodging guest rooms, multi-bedroom housing units in undergraduate student housing and residential dwelling units; and shall...
-
11B-213.3.6 Bathing facilities
Transfer type shower compartments shall be permitted in transient lodging guest rooms, multi-bedroom housing units in undergraduate student housing and residential dwelling units; and shall...
-
M304 Diagnostic Equipment Used by Patients in Standing Position
disabilities in a standing position where standing supports are provided, in a seated position where a folding or removable seat is provided, and seated in a wheelchair where a wheelchair space...
- Guldmann Basic High Bariatric Sling, 1100 lbs / 500 kg
-
Re: Lavatories Adjacent to Partitions
sidewall or partition to be a minimum of 18" to the centerline of the fixture without reference to dispensers or similar elements (as commented previously). 11B-606.2 requires clear floor space...
-
7.3 Imaging System Accessibility Configuration Examples and Concerns
This would reduce the distance between the floor and the transfer surface....
-
11B-809.2.1 Location
At least one accessible route shall connect all spaces and elements which are a part of the residential dwelling unit....