(ii) Where existing shaft or structural elements prohibit strict compliance with 4.10.9, then the minimum floor area dimensions may be reduced by the minimum amount necessary, but in no...
Search Results "Floor Slope"
-
4.1.6(4)(c)
-
5.2 FOOD SERVICE LINES
Tray slides shall be mounted no higher than 34 in (865 mm) above the floor. If self-service shelves are provided, a reasonable portion must be within the ranges shown in Fig. 53....
-
4.34.6.6* RANGES AND COOKTOPS
The clear floor space may overlap the knee space, if provided, by 19 in (485 mm) maximum. The location of controls for ranges and cook-tops shall not require reaching across burners....
-
1134A.8, Item 4.3
The clear floor space required by Item 2 shall not extend into the knee and toe space more than 19 inches (483 mm). (See Figure 11A-9D)....
-
Are closet doors and pantry doors required to comply?
cabinets and other storage elements not providing user passage do not have to comply with provisions for doors, but must meet requirements for storage (§811), including those for clear floor...
-
11B-407.2.2.1 Visible and audible signals
Where in-car signals are provided, they shall be visible from the floor area adjacent to the hall call buttons. Exceptions: 1. Reserved. 2. Reserved. [2010 ADAS] 2....
-
11B-604.9.5 Flush controls
Hand operated flush controls shall comply with Sections 11B-309.2 and 11B-309.4 and shall be installed 36 inches (914 mm) maximum above the finish floor....
-
Design Opportunity
27" AFF under the vanity top (306) while keeping the counter/rim at 34" AFF maximum (606.3); and it may require more than 8" minimum knee clearance to provide the extended depth clear floor...
-
This is a great unit but it's not "recessed", it's semi-recessed.
If you place this unit next to the accessible lavatory or other required clear space and don't allow room for the projection, it may interfere with the minimum required clear floor space...
-
Non-Positive Shut-off
Remember that the hose has to be at least 59" long so it would fall onto the floor of the tub if dropped. It's a plumbing safety requirement....
-
11B-604.6 Flush controls
Hand operated flush controls shall comply with Section 11B-309 except they shall be located 44 inches (1118 mm) maximum above the floor....
-
1009.9 Signage
Signage indicating special accessibility provisions shall be provided as shown: Each door providing access to an area of refuge from an adjacent floor area shall be identified by a...
-
1009.9 Signage
Signage indicating special accessibility provisions shall be provided as shown: Each door providing access to an area of refuge from an adjacent floor area shall be identified by a...
-
11B-604.6 Flush controls
Hand operated flush controls shall comply with Section 11B-309 except they shall be located 44 inches (1118 mm) maximum above the floor....
-
11B-220.1.2 Two automatic teller machines or fare machines
or fare machines are provided at a location, one shall comply with Sections 11B-707.2 through 11B-707.8 and one shall comply with Sections 11B-309 _|Operable Parts|_, 11B-707.2 _|Clear Floor...
-
4.1.7(3)(e)
., open books), should be no higher than 44 in (1120 mm) above the floor surface....
-
4.1.6(3)(e)(i)
(i) Where it is technically infeasible to comply with 4.22 or 4.23, the installation of at least one unisex toilet/bathroom per floor, located in the same area as existing toilet facilities...
-
Disability Discrimination
Disability Discrimination Authorities on disability have often said, and I have quoted them on this floor before, that the history of society’s formal methods of dealing with people with...
-
4.1.6(3)(c)
(ii) At least one toilet facility for each sex on each substantially altered floor, where such facilities are provided, complying with 4.22, Toilet Rooms; and 4.23, Bathrooms, Bathing Facilities...
-
2.3.2
For example, floor profilers can provide a very accurate measurement of surface flatness but are expensive and require training to use....
-
III-5.4300 Transportation terminals
services in a two-story facility - including boarding, debarking, loading and unloading, baggage claim, dining facilities, and other common areas open to the public - are located on the same floor...
-
1132A.4.1 Thresholds
., floor material changes at door thresholds) shall not exceed ½ inch (12.7 mm). Thresholds shall comply with the following:...
-
11B-809.10.8.1 Location
The top of the lavatory rim shall be 34 inches (864 mm) maximum above the finished floor....
-
11B-809.9.4 Work surfaces
Work surfaces shall be 36 inches (914 mm) maximum above the finish floor with minimum lengths at the following locations as required by this section: Linear length of 30 inches...