7. Amend 28 CFR part 35 by adding § 35.138 to read as follows:
Search Results "Centered Clear Floor Space"
-
7. Amend 28 CFR part 35 by adding § 35.138 to read as follows:
-
§ 35.138 Ticketing
§ 35.138 Ticketing.
-
§ 36.302(f)(1)(ii) Ticket sales
(ii) Ticket sales. A public accommodation that sells tickets for a single event or series of events shall modify its policies, practices, or procedures to ensure that individuals...
-
Location and Dispersion
[See subsections ...]
- 2017 National ADA Symposium
-
904.4 Sales and Service Counters
reduction of the number of existing mail boxes, the counter shall be permitted to have a portion which is 24 inches (610 mm) long minimum complying with 904.4.1 provided that the required clear...
-
904.4 Sales and Service Counters
reduction of the number of existing mail boxes, the counter shall be permitted to have a portion which is 24 inches (610 mm) long minimum complying with 904.4.1 provided that the required clear...
-
Re: Husky 24" Line Generator Digital Laser Level
See Bill Hecker, AIA, Kirola vs City and County of San Francisco, Expert for DOJ, testimony with regards to Laser level lengths.
-
11B-608.2.2 Standard roll-in type shower compartments
Standard roll-in type shower compartments shall be 30 inches (762 mm) wide minimum by 60 inches (1524 mm) deep minimum clear inside dimensions measured at center points of opposing sides...
-
11B-608.2.2 Standard roll-in type shower compartments
Standard roll-in type shower compartments shall be 30 inches (762 mm) wide minimum by 60 inches (1524 mm) deep minimum clear inside dimensions measured at center points of opposing sides...
-
Angled Van Spaces
As with regular accessible spaces, van accessible spaces can share a common access aisle....
- Seton Custom SetonGlo™ Floor & Stair Identification Signs AV0154
-
g-iii
Is there clear maneuvering floor space in front of each accessible door (see ADA Standards § Fig. 25) and, on the pull side, is there at least 18 inches clear floor space beyond the latch...
-
5.3.3.3 Location Where Walls Not Provided
Where walls or partitions are not provided, the seat shall be positioned in a corner of the clear floor or ground space required by 5.3.2 for a left-hand or right-hand approach. ...
-
5.3.3.3 Location Where Walls Not Provided
Where walls or partitions are not provided, the seat shall be positioned in a corner of the clear floor or ground space required by 5.3.2 for a left-hand or right-hand approach....
-
405.9.1 Extended Floor or Ground Surface
The floor or ground surface of the ramp run or landing shall extend 12 inches (305 mm) minimum beyond the inside face of a handrail complying with 505....
-
Stages.
estimates significant costs, regardless of the baseline used, for the proposed requirement that court facilities must provide an accessible route to a witness stand or attorney area and clear...
-
11B-703.8.9 Height above floor
11B-703.8.9 Height above floor. Low resolution VMS characters shall be 40 inches (1016 mm) minimum above the floor of the viewing position, measured to the baseline of the character. ...
-
11B-703.8.9 Height above floor
11B-703.8.9 Height above floor. Low resolution VMS characters shall be 40 inches (1016 mm) minimum above the floor of the viewing position, measured to the baseline of the character....
-
M14
Is the operating control (switch, lever, button, or pull) for each type of dispenser or built-in equipment no higher than 54 inches above the floor (if there is clear floor space for a parallel...
- Inpro Corporation ENDURANT® Floor-Mounted Overhead-Braced Partitions
-
Parking sign height measurement technique
502.6 says "Signs shall be 60 inches (1525 mm) minimum above the finish floor or ground surface measured to the bottom of the sign." But which floor or ground surface? ...
-
M7
If the door swings into the room, does the door swing not overlap the required clear floor space for the toilet or lavatory?...
-
11B-904.4 Sales and service counters
the number of existing mail boxes, the counter shall be permitted to have a portion which is 24 inches (610 mm) long minimum complying with Section 11B-904.4.1 provided that the required clear...