., books, should be no higher than 44 in (1120 mm) above the floor surface....
Search Results "Ground Floor Exit"
Commonly Searched Documents
- 
    
  
  4.1.7(2)(e)
  
 - 
    
  
  1132A.10 Door signal devices
  
The activating mechanism shall be mounted a maximum of 48 inches (1219 mm) above the floor and connected to permanent wiring....
 - 
    
  
  1134A.7, Item 4
  
Water closet controls shall be mounted no more than 44 inches (1118 mm) above the floor. The force required to activate controls shall be no greater than 5 pounds (22.2 N)....
 - 
    
  
  § 38.79(b)
  
(b) All thresholds and step edges shall have a band of color(s) running the full width of the step or threshold which contrasts from the step tread and riser or adjacent floor, either light-on-dark...
 - 
    
  
  § 38.117(b)
  
(b) All step edges and thresholds shall have a band of color(s) running the full width of the step or threshold which contrasts from the step tread and riser or adjacent floor, either light-on-dark...
 - 
    
  
  11B-903.6 Structural strength
  
Benches shall be affixed to the wall or floor....
 - 
    
  
  § 38.99(b)
  
(b) All thresholds and step edges shall have a band of color(s) running the full width of the step or threshold which contrasts from the step tread and riser or adjacent floor, either light-on-dark...
 - 
    
  
  11B-604.8.3 Coat hooks and shelves
  
Shelves shall be located 40 inches (1016 mm) minimum and 48 inches (1219 mm) maximum above the finish floor....
 - 
    
  
  1132A.10 Door signal devices
  
The activating mechanism shall be mounted a maximum of 48 inches (1219 mm) above the floor and connected to permanent wiring....
 - 
    
  
  Height: ADA Standard Section 704.4.1
  
When in use, the touch surface of TTY keypads shall be 34 inches (865 mm) minimum above the finish floor....
 - 
    
  
  Shower Compartment Seats: ADA Standard Section 610.3
  
Section 610.3 covers the current ADA Standards for shower compartment seats.
 - 
    
  
  1009.6.3 Size
  
Exception: The enforcing agency may reduce the size of each required area of refuge to accommodate one wheelchair space that is not less than 30 inches by 48 inches (762 mm by 1219 mm) on floors...
 - 
    
  
  b. Exception for Base Support Allowance and Unobstructed Knee and Toe Space
  
, which can extend to a height of 4 inches above the floor at a depth of 28 inches....
 - 
    
  
  1016.4.1 Size
  
Where the passing space is the intersection of two outdoor recreation access routes, the intersection must be as flat as possible so that all of the wheels of a mobility device touch the ground...
 - 
    
  
  1016.9 Protruding Objects
  
entities should maintain the vertical clearance along outdoor recreation access routes, resting intervals, and passing spaces free from tree branches for 80 inches high minimum above the ground...
 - 
    
  
  1016.4.1 Size
  
Where the passing space is the intersection of two outdoor recreation access routes, the intersection must be as flat as possible so that all of the wheels of a mobility device touch the ground...
 - 
    
  
  A4.3.1(1) Travel Distances
  
This assumes a rate of about 1.5 ft/s (455 mm/s) on level ground. It also assumes that the traveler would move continuously....
 - 
    
  
  Alterations [4.1.6(1)(f) & (k)]
  
Thus, the exception from the requirement for an elevator in buildings with less than 3 stories or with less than 3,000 square feet per floor applies to altered facilities as well, including...
 - 
    
  
  Guest Rooms
  
At least on sleeping area shall provide a clear floor space complying with 305 on both sides of a bed....
 - 
    
  
  Feminine product dispensers
  
For purposes of resolving this matter, the Museum will provide, on each floor, at least one feminine product dispenser in the women's toilet rooms that does not requires tight grasping and...
 - 
    
  
  1i
  
Are all of the small showers free of curbs or lips greater than 1/2" high at the shower floor that would impede wheelchair approach and transfer onto the folding shower seat?...
 - 
    
  
  Volume Controls
  
Do at least 25% (not less than one) of all other house phones on each floor have volume controls? Yes __ No __ N/A __ Comments: ___________________________________________...
 - 
    
  
  Volume Controls
  
Do at least 25% (not less than one) of all other pay phones on each floor have volume controls? Yes __ No __ N/A __ Comments: ___________________________________________...
 - 
    
  
  Volume Controls
  
Do at least 25% (not less than one) of all other pay phones on each floor have volume controls? Yes __ No __ N/A __ Comments: ___________________________________________...