facilities and equipment (including, but not limited to, permanent equipment such as lifts and elevators, and temporary equipment such as portable ramps, traffic cones, signs, wedges, and door...
Search Results "Door Height"
Commonly Searched Documents
-
A. Accessible Voting Program
-
II-6.5000 Alterations to historic properties
There appears, however, to be a problem if one of the interior doors is widened, because historic decorative features on the door might be destroyed....
-
11B-703.6.1 Pictogram field
Pictograms shall have a field height of 6 inches (152 mm) minimum. Characters and Braille shall not be located in the pictogram field. Advisory 11B-703.6.1 Pictogram field. ...
-
1. Measuring Tape
A metal measuring tape is an essential tool for a successful survey because many of the accessibility requirements concern the width, height, or depth of various features....
-
Signs
Signs that provide direction to, or information, about functional spaces must only comply with requirements for character proportion, character height, and finish and contrast between the...
-
Alteration
rehabilitation, reconstruction, historic restoration, changes or rearrangement of the structural parts or elements, and changes or rearrangement in the plan configuration of walls and full-height...
-
Verify Rough Plumbing
Location of lavatory traps from side walls. 11B-606.6 Location of bathtub controls and drain. 11B-607.5 Installation height...
-
4.29.2* Detectable Warnings on Walking Surfaces
Detectable warnings shall consist of raised truncated domes with a diameter of nominal 0.9 in (23 mm), a height of nominal 0.2 in (5 mm) and a center-to-center spacing of nominal 2.35 in...
-
Verify Rough Plumbing
Location of lavatory traps from side walls. 11B-606.6 Location of bathtub controls and drain. 11B-607.5 Installation height...
-
4.1.3 Wheelchair Seating Space
Toe clearance of at least 9 inches (230 mm) in height shall extend at least an additional 5 inches (125 mm) from the knee clearance....
-
Knee Clearance: Clearance as Measured from Anterior-Most Point - Manual Wheelchair
It references dimensions of clearance height and depth to the forward-most point on the person or mobility device (e.g., toe, footrest)....
-
Knee Clearance: Clearance as Measured from Dorsal Foot Point - Manual Wheelchair
It references dimensions of clearance height and depth to the dorsal foot point on a person (e.g., top of ankle)....
-
M303.2.4.2 Knee Clearance
Between 9 inches (230 mm) and 27 inches (685 mm) above the floor, the knee clearance shall be permitted to reduce at a rate of 1 inch (25 mm) in depth for every 6 inches (150 mm) in height...
-
11B-707.9.1.1 Tactilely discernible numerical keypad
A tactilely discernible numerical keypad similar to a telephone keypad containing a raised dot with a dot base diameter between 1.5 mm and 1.6 mm and a height between 0.6 mm and 0.9 mm on...
-
R302.2 Components
Doors, doorways, and gates complying with section 404 of Appendix D to 36 CFR part 1191. Advisory R302.2 Components....
-
City of XXX – ADA Transition Plan
Facilities manager $450 Maintenance and repairs City Council room Inadequate maneuvering clearance at entrance door...
-
Exception 4
Widening doors. Installing offset hinges to widen doorways. Eliminating a turnstile or providing an alternative accessible route. Installing accessible door hardware....
- Rakks® Brackets Installation Video
-
11B-703.7.2.6.1 Men’s toilet and bathing facilities
The triangle symbol shall contrast with the door, either light on a dark background or dark on a light background....
-
11B-213.2.1 Unisex (single-use or family) toilet and unisex bathing rooms
Doors to unisex toilet rooms and unisex bathing rooms shall have privacy latches....
-
11B-612.2 Bench
Doors shall not swing into the clear floor space required by Section 11B-903.2....
-
11B-505.2 Where required
At door landings, handrails are not required when the ramp run is less than 6 inches (152 mm) in rise or 72 inches (1829 mm) in length....
-
11B-703.7.2.6.1 Men’s toilet and bathing facilities
The triangle symbol shall contrast with the door, either light on a dark background or dark on a light background....
-
1. General Exception
Some specific examples include: Dual Energy X-Ray Absorptiometry (DXA) machines, with a mechanism that moves imaging components along a track beneath the patient surface precluding height...